My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2000_2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
ARCHIVED REPORTS
>
ARCHIVED REPORTS_2000_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2020 5:29:16 AM
Creation date
7/3/2020 10:41:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2000_2
RECORD_ID
PR0440004
PE
4433
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
01
SITE_LOCATION
6484 N WAVERLY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440004_6484 N WAVERLY_2000_2.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
221
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APPENDIX D <br /> STATISTICAL METHODS TO DETERMINE CONCENTRATION LIMITS <br /> Tolerance Limit Methodologies <br /> The purpose of a tolerance interval approach is to define a concentration range from background <br /> well data,within which a large proportion of the monitoring observations should fall with a high <br /> probability. The proportion of the population included is referred to as the coverage. The <br /> probability with which the tolerance interval includes the proportion of the population is referred <br /> to as the tolerance coefficient. <br /> Consistent with USEPA and state recommendations, Sanitas (computer program utilized)uses a <br /> 95 percent coverage and 95 percent tolerance coefficient. The upper 95 percent tolerance limit <br /> will contain at least 95 percent of the distribution of observations from background well data. <br /> The tolerance interval method is described in the following documents: <br /> -- Introduction to Statistical Quality Control,D.C. Montgomery. John Wiley <br /> Publishing,New York. 1985. <br /> -- Statistical Analysis of Groundwater Monitoring Data at RCRA Facilities,Interim <br /> Final Guidance Document,USEPA. USEPA/530-SW-89-026. February 1989. <br /> -- Statistical Analysis of Groundwater Monitoring Data at RCRA Facilities, <br /> Addendum to Interim Final Guidance, USEPA. USEPA/530- -93-003. July <br /> 1992. <br /> San Joaquin County uses Groundwater Statistical Analysis System(DSAS, now referred to as <br /> Sanitas)to calculate tolerance limits for County Landfills. Sanitas is a statistical software <br /> program developed by Intelligent Decision Technologies, Ltd. (IDT). It is specifically designed <br /> to evaluate water quality monitoring data for landfills. Sanitas performs all pre- and post- <br /> analysis tests required so that the data do not violate size and distribution assumptions of the <br /> relevant statistical analysis. <br /> Within Sanitas,the EPA Standards are used to evaluate all data. Statistical Outliers are removed <br /> prior to running any analytical methods. <br /> Parametric Tolerance Limit <br /> When conducting the tolerance interval method, Sanitas automatically evaluates the distribution <br /> of the data. Within Sanitas,the County selects the Coefficient of Variation test for normality to <br /> be applied. Sanitas applies the parametric tolerance limit test when the background data set is <br /> found to have less than 50 percent non-detects and the background data have a normal or <br /> transformed normal distribution. If greater than 15 percent but less than 50 percent of the <br /> background data set consist of non-detect values, the mean and standard deviation of the data set <br /> are adjusted using the Aitchison's Method. The tolerance limit is then calculated using the <br /> adjusted values. <br /> Foothill Sanitary Landfill Department of Public Works/Solid Waste <br /> e Quarter and Annual 2002 Groundwater Monitoring Report D- 1 County of San Joaquin <br />