Laserfiche WebLink
Foothill Sanitary Landfill — Module 1 December 2003 <br />County of San Joaquin Job No. 031602.00.02 <br />Five (5) geocomposite samples were tested for conformance testing. Based on <br />approximately 345,000 ft2 of geocomposite used, this testing frequency correspond to <br />one test per 69,000 ft2,, which satisfies the requirement of one test per 100,000 square <br />feet (ft2). Results of the conformance testing indicated that the materials met the <br />requirements of the project specifications. A summary of the geocomposite <br />conformance testing is shown in Table 7. Detailed test results are provided within <br />Appendix M. <br />5.5.3 Deployment <br />The panel deployment procedure was observed and documented by Vector's CQA <br />Monitor. Our CQA Monitor verified that the conditions of the CQA manual were met <br />during deployment. Vector's CQA Monitor continuously observed deployment activities <br />to ensure no damage occurred to the underlying components. <br />Vector Engineering, Inc. • 143E Spring Hill Drive • Grass Valley, CA 95945 • (530) 272-2448 <br />38 <br />