My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
ARCHIVED REPORTS
>
ARCHIVED REPORTS_2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:21 PM
Creation date
7/3/2020 10:42:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2004
RECORD_ID
PR0440004
PE
4433
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
01
SITE_LOCATION
6484 N WAVERLY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440004_6484 N WAVERLY_2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
574
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
extrapolation with time temperature superposition principals. Creep <br /> rupture testing is required on representative samples of the finished <br /> product and not a single component of the geogrid (e.g., fiber and/or yarn). <br /> Creep rupture testing that has been performed through the use of <br /> alternative techniques (e.g., stepped Isothermal Method) must be <br /> supported with Creep rupture data conducted for a minimum of 10,000 <br /> hours at 20 degrees C. <br /> In no event shall the minimum value of FSCR be less than 2.3 for HDPE <br /> uniaxial geogrid <br /> The load applied for the test duration must equal or exceed the percentage <br /> of ultimate representing the creep rupture strength of the product. The <br /> percentage of ultimate is defined as the inverse of the FSCR or 1/FSCR. The <br /> ultimate strength used in this calculation shall be that of the roll used in <br /> the testing and not the MARV for the product. <br /> C. RFID - Reduction Factor for Installation Damage shall be determined from <br /> construction damage tests for each product proposed in accordance with <br /> ASTM D5818-95. Tests shall be conducted using the actual backfill from <br /> the project. However, in lieu of such testing, the Manufacturer can supply <br /> test results from other backfill soils if such soils can be shown to result in <br /> more severe construction damage than the proposed backfill. Testing shall <br /> be consistent with ASTM D5818-95. <br /> d. RFD - Reduction Factor for Durability/Aging is the combined partial factor <br /> for potential chemical and biological degradation. RFD shall be determined <br /> from polymer specific (HDPE and PP as identified by their mechanical <br /> properties, and PET as identified by CEG number and number average <br /> molecular weight, Mn) durability testing covering the range of expected <br /> soil environments. Polyolefin geogrids can be used in a pH range from 2 to <br /> 12, and polyester geogrids can be used within a pH range of greater than 3 <br /> and less than 9. The minimum Reduction Factor for Durability/Aging for <br /> HDPE and PP shall be 1. <br /> Forward Landfill WMU FU-04 <br /> 02779 5 GEOGRID <br />
The URL can be used to link to this page
Your browser does not support the video tag.