Laserfiche WebLink
o`t V�N nCCeg0 9 <br /> —=== <br /> ENVIRONMENTAL w 6 ,°e <br /> -q, s <br /> JanuaryIl@' 'ICAL CHEMISTS Lab ID STK651133 <br /> San Joaquin County Solid Waste Customer : 3-2956 <br /> Quality Control - Inorganic <br /> Constituent Method Date/ID Type Units Cone. 2CData DQO Nate <br /> Metals <br /> Iron 3010A 01/04/2007:A207 Blank mg/L ND <0.05 <br /> LCS mg/L 4.000 101% 85-115 <br /> PDS mg/L 4.000 108% 75-125 <br /> MS mg/L 4.000 106% 75-125 <br /> (SP 613432-0I) MSD mg/L 4.000 110% 75-125 <br /> MSRPD mg/L 2.5% 520.0 <br /> 200.7 01/05/2007:A 00-ICB ppm ND <0.05 <br /> 00-CCB ppm ND <0.05 <br /> 00-ICV ppm 5.000 100% 95-105 <br /> 00-CCV ppm 5.000 100% 90-110 <br /> Wet Chem <br /> Conductivity 2510B 12/29/2006:A212 Blank umhos/cm ND <1 <br /> Dup umhos/cm 0.0% 0.372 <br /> 2510B 12/29/2006:A 00-ICB umhos/cm ND <1 <br /> 00-ICV umhos/cm 10000 101% 95-105 <br /> 00-CCV umhos/cm 1002 99.7% 95-105 <br /> Oil and Grease 1664 12/29/2006:A253 Blank mg/L ND <3 <br /> LCS mg/L 40.40 80.7% 66-123 <br /> BS mg/L 40.40 78.6% 63-121 <br /> BSD mg/L 40.40 70.4% 63-121 <br /> BSRPD mg/L 10.5% 548.9 <br /> PH 4500-H B 12/27/2006:S346 Dup units 0.2% 0.945 <br /> 4500-H B 12n7/2006:S 00-CCV units 8.000 99.5% 95-105 <br /> Solids, Total Suspended (TSS) 2540D 12/28/2006:A236 Blank mg/L ND <10 <br /> LCS mg/L 500.0 83.2% 38-138 <br /> Dup mg/L 2.0 10 <br /> DefmiElotss <br /> Blank Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br /> LCS Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte <br /> recovery. <br /> PDS Past Digestion Spike (ICP/GFAA) <br /> MS/MSD Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication oil <br /> how that sample matrix affects analyte recovery. <br /> BS/BSD Blank Spikes - A blank is spiked with a known amount of analyte. It is prepared to verify that the preparation <br /> process is not affecting analyte recovery. <br /> Dup Duplicate Sample - A random sample with each batch is prepared and analyzed in duplicate. The relative percent <br /> difference is an indication of precision for the preparation and analysis. <br /> 1CB Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> ICV : Initial Calibration Verification - Analyzed to verify the instrument calibration Is within criteria, <br /> CCB Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br /> CCV Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br /> ND Non-detect - Result was below the DQO listed for the analyte. <br /> DQO Data Quality Objective This is the criteria against which the quality control data is compared. <br /> STK651133: Quality Control Page 1 <br /> Corporate Offices&Laboratory Office&Laboratory Field Office <br /> P.O.Box 272/853 Corporation Street 2500 Stagecoach Road Visalia,California <br /> Santa Paula,CA 93061-0272 Stockton,CA 95215 TEU (559)734-9473 <br /> TEL (805)392-2000 TEL (209)942-0181 FAX: (559)734-8435 <br /> FAX: (805)525-4172 FAX (209)942-0423 Mobile: (559)737-2399 <br /> CA NELAP Certification No.01110CA CA ELAP CartlOcation No.1563 <br /> CA FLAP Certification No.1573 <br />