Laserfiche WebLink
MONITORING WELL PURGING PROTOCOL <br /> MEASURE AND RECORD DEPTH TO WATER AND <br /> U0 <br /> WELL TOTAL DEPTH <br /> OWT <br /> CALCULATE PURGE VOLUME BY <br /> USING THE FOLLOWING EQUATION: <br /> P=7tehx7.48x3 <br /> i <br /> where: <br /> i <br /> P=calculated purge volume(gallons) <br /> =3.14 <br /> f <br /> r=radius of well casing in feet <br /> h=height of water column in feet <br /> I <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> THE CALCULATED PURGE VOLUME WHILE <br /> MONITORING GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETERS j <br /> (pH,CONDUCTIVITY,TEMPERATURE)AT 1 <br /> INTERVALS OF ONE CASING VOLUME. <br /> WELL EVACUATED TO PRACTICAL LIMITS <br /> OF DRYNESS BEFORE REMOVING <br /> CALCULATED PURGE VOLUME I <br /> I <br /> I <br /> NO YES <br /> FINAL TWO SETS OF GROUNDWATERSTABILIZATION INDICATOR PARAMETER <br /> MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA: WELL RECHARGES TO A LEVEL <br /> pH = 0.1 pH units SUFFICIENT FOR SAMPLE <br /> COND. = 10% COLLECTION WITHIN 24 HOURS i <br /> TEMP, =t 1,0 OF OF EVACUATION TO DRYNESS. <br /> E <br /> YES NO YES NO t <br /> WELL PURGING CONTINUE PURGING;EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET, ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER,MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> WELL SAMPLING. INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING. <br /> STABILITY. SAMPLING. <br /> FIGURE <br /> C MONITORING WELL PURGING PROTOCOL A-1 <br />