Laserfiche WebLink
U <br />Foothill Landfill Monthly "Standard Observations" <br />as described in the Standard Provisions and Reporting Requirements <br />File LA -31103-B <br />Date: Jan 9, 2013 Time In: 10:00 am Time Out: 2:00 pm Observer: B Closs <br />Location <br />Observation <br />Comments/Observations <br />General <br />Weather conditions: wind direction and velocity, <br />recent precipitation <br />Overcast skies, 3 MPH breeze out of SSE; 43° F <br />Baro Pressure 30.04" Hg and falling <br />Receiving <br />Waters <br />Discoloration and turbidity: description, source, and <br />size of affected area <br />None observed <br />Evidence of odors: characterization, source, and <br />distance from source <br />None observed <br />Evidence of water uses: presence of water <br />associated wildlife <br />No Evidence <br />Flow rate of water from WMU <br />No flow rate <br />Floating and suspended materials of waste origin: <br />source and size of affected area <br />None observed <br />Perimeter of <br />WMU <br />Evidence of liquid leaving or entering the unit: size of <br />affected area, flow rate (show on map) <br />None observed <br />Evidence of odors: characterization, source, and <br />distance from source <br />No Evidence <br />Evidence of erosion and/or of daylighted refuse <br />No Evidence <br />For the WMU <br />Evidence of ponded water at any point on the waste <br />management facility (show on map) <br />No Evidence <br />Evidence of odors: characterization, source, and <br />distance from source <br />Mild odor at working face <br />Evidence of erosion and/or of daylighted refuse <br />No Evidence <br />Additional remarks: <br />Leachate meter readings <br />Sump Level <br />Pre -pumping 28.7 <br />— <br />Inches <br />Secondary sump: Vol pumped 3668 gal <br />While pumping 28.5 <br />Inches <br />Condensate level 1.6 in. we <br />Mode: uto anual <br />Volume 2,292,200 <br />Gal <br />Instantaneous flow rate 40 <br />gpm <br />pH. 6.2 <br />E.C.: 1798 <br />Leak in leachate line immediately before filter <br />leak at Cock valve <br />Simulate Hi Hi Sump Alarm X <br />Repaired leak on leachate line before cut off valve <br />Authorized non -solid waste related discharges observed? (y/n) NO <br />Light lit at leachate tank? jC Yes I lNo <br />Un -authorized non -solid waste related discharges observed? (y/n) NO <br />Indications of prior unauthorized non -solid waste related discharge? (y/n) NO <br />Reset alarm at leachate tank 1Z <br />If yes, note on separate sheet <br />Note area of fill on map <br />Original to file <br />N:\1Foothill\Groundwater Monitoring\Repts2013\1st Semester\STD_OBS 1Sam 2013.As, Sheet FH Jan <br />Printed 6/1 812 01 3 <br />