Laserfiche WebLink
f <br /> i <br /> 1 <br /> Table Am2 <br /> Analytical Test Methods and Sample Holding Times <br /> a � <br /> Parameter Matrix Test Method Holding Time I <br /> Volatile Organic 8260B or 601 Series i I <br /> Compounds 14 days <br /> Metals <br /> 6000 and 7000 6 months' ! <br /> Series 1 <br /> Hexavalent Chromium 7199 24 hours j <br /> Alkalinity(carbonate, 310.1 14 days f <br /> bicarbonate total) <br /> Chemical Oxygen Demand 410.2 28 days <br /> Chloride 300. 28 days <br /> Nitrate+nitrite as Nitrogen 353.2 14 days <br /> i <br /> Y <br /> Sulfate 300 28 days <br /> Sulfide 9030B 7 days <br /> Total Dissolved Solids 160.1 7 days <br /> Total Organic Carbon 415.1 28 days <br /> Semi-volatile organic 8270 7 days to extraction <br /> compounds <br /> Organophosphorous 8141 7 days to extraction <br /> compounds <br /> Chlorophenoxy Herbicides 8151A 7 days to extraction ! <br /> Cyanide 9010B 14 days <br /> Oil and Grease 413.2 28 days <br /> 'Metals analyzed by ICP(USEPA Method 6010),with the exception of antimony(USEPA Method 7041),arsenic <br /> (USEPA Method 7062),cadmium(USEPA Method 7131A),lead(USEPA Method 7421),mercury(USEPA Method <br /> 7470A),nickel(USEPA Method 7521),selenium(USEPA Method 7742),and thallium(USEPA Method 7841). <br /> n Holding time for all metals is 6 months,with the exception of mercury(28 days). j <br /> j <br /> NaMiscellaneouslGroundwalerImfo-Ali SlteslSAP AppendixA.doc <br /> i <br /> E <br /> j <br /> i <br /> 1 <br /> Groundwater Monitoring A-10 Department of Public Works/Solid Waste <br /> County of San Joaquin <br /> I <br /> i <br /> i <br />