My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WAVERLY
>
6484
>
4400 - Solid Waste Program
>
PR0440004
>
ARCHIVED REPORTS
>
ARCHIVED REPORTS_2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:49 PM
Creation date
7/3/2020 10:46:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2015
RECORD_ID
PR0440004
PE
4433
FACILITY_ID
FA0004517
FACILITY_NAME
FOOTHILL LANDFILL
STREET_NUMBER
6484
Direction
N
STREET_NAME
WAVERLY
STREET_TYPE
RD
City
LINDEN
Zip
95236
APN
09344002
CURRENT_STATUS
01
SITE_LOCATION
6484 N WAVERLY RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440004_6484 N WAVERLY_2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
724
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Taj Bahadori <br />July 13, 2015 <br />Page 5 of 6 <br />Test Series 3 — GM/Geocomposite (GC) Interface <br />• The post -peak strengths for this interface for the side slope liner met the <br />minimum specified values at normal stresses of 6,000, 8,000 and 12,000 psf, but <br />were slightly below the specified values at normal stresses of 1,000 and 4,000 psf. <br />• The specified minimum post -peak value of 404 psf at 1,000 psf normal stress <br />corresponds to a secant friction angle of 22 degrees, which is unrealistic and <br />practically unachievable for the materials specified. The measured post -peak <br />strength was 372 psf, corresponding to a secant angle of 20 degrees which is in <br />line with available data base (typically 18 to 20 degrees). <br />• The post -peak strength at 4,000 psf normal stress was measured at 1,154 psf, <br />slightly below the specified value of 1,174 psf. <br />4.2 Multi -Laver (Sandwich) Interface Tests <br />Test Series 4 — Base Liner <br />• The test results indicate that the specified post -peak strength values were <br />achieved at all 5 normal stress points. <br />• The sliding occurred on the GCL/GM interface. At 12,000 psf normal stress, it <br />eventually resulted in GCL internal failure but the measured post -peak strength <br />was 1,575 psf vs. specified minimum value of 1,555 psf. This result was on GCL <br />sample with the lowest peel strength (47.5 lbs). The retest, at 12,000 psf normal <br />stress, using GCL sample with a peel strength of 53.6 lbs, showed a post -peak <br />strength of 2,391 psf with partial internal failure of GCL. <br />• This sandwich test, therefore, confirmed that the lowest post -peak strength was <br />measured on the GCL/GM interface. The test results from either the sandwich <br />Test Series 4 or from the single interface test, Series 2 for GCL/GM interface, <br />may be used for the base liner in stability calculations. <br />Test Series 5 — Side Slope Liner <br />• Both the peak and post -peak strengths for Test Series 5 are in close agreement <br />with single interface Test Series 3 for GM/GC interface. The failure/sliding <br />occurred on GM/GC interface for all 5 normal stresses. <br />PA14 Projects\14-101 ( SJCDPW North County and Foothill)\Correspondence\Memo - Foothill Interface Shear Strength Test Results.docx <br />
The URL can be used to link to this page
Your browser does not support the video tag.