Laserfiche WebLink
• <br />r. <br />E <br />0 <br />C <br />I <br />F <br />2 1 3 1 4 1 5 1 6 1 7 1 8 <br />5 6 1 7 1 8 <br />CONTROL DIAGRAM SYMBOLS <br />WIRING DEVICES <br />MOTORS AND EQUIPMENT <br />ONE—LINE DIAGRAM SYMBOLS <br />120V <br />CONTROL RELAY <br />SWITCHES: <br />--- <br />CONTROL TRANSFORMER, PRIMARY <br />OPERATING COIL <br />EP <br />DISCONNECT SWITCH, NON-FUSED <br />I SIZE 2 COMBINATION FULL VOLTAGE �� POWER TRANSFORMER. <br />�� <br />AND SECONDARY VOLTAGES SHOWN, <br />���^��� <br />NON -REVERSING MAGNETIC STARTER 5.75% Z 480/277V IMPEDANCE SHOWN <br />�_ <br />SIZE AS SHOWN OR SPECIFIED <br />CR CR = CONTROL RELAY <br />U <br />UNLESS OTHERWISE SPECIFIED, ALL SWITCHES <br />J MCP SIZED BY MANUFACTURER <br />120V <br />U = UNLATCH <br />FUNCTION L = LATCH <br />ARE WALL MOUNTED. <br />M <br />O <br />MOT -MOTOR <br />SV -SOLENOID VALVE <br />(OVERLOAD RELAY NOT SHOWN) <br />I RV = REDUCED VOLTAGE <br />CV=CONTROL VALVE <br />1 2S2W = TWO -SPEED TWO -WINDING 480V <br />\ <br />CIRCUIT BREAKER, THERMAL- <br />MAGNETIC, 3 POLE, UON, <br />TOGGLE SWITCH, SINGLE POLE, <br />A=ADJUSTABLE SPEED DRIVE <br />2 = SIZE 2 30, 4W GENERATOR. POWER RATING, <br />140A <br />RATING IN AMPS <br />OL <br />20 AMP <br />T2 600KW FREQUENCY, VOLTAGE, <br />�.X— THERMAL OVERLOAD RELAY <br />125 = 125HP <br />60HZ <br />2CR 2CR <br />GANGED SWITCHES IN COMMON BOX <br />FIELD INSTRUMENT <br />SHOWN <br />DESIGNATES PLC INPUT <br />WITH COMMON WALL PLATE <br />400/3 <br />TERMINATION OR CONTROL <br />PANEL TERMINATION <br />-{�- OUTPUT CONTACTS <br />CONTROL STATION. SEE CONTROL <br />" <br />CURRENT TRANSFORMER WITH <br />RATIO AND NUMBER OF UNITS <br />Ip <br />�D <br />FUSE <br />2 TIMING RELAY <br />SUPERSCRIPT INDICATES CIRCUIT <br />CONTROLLED: o, b, c, ETC. MAY BE <br />DIAGRAMS FOR DEVICES REQUIRED <br />3 _� <br />200 AMP SHOWN <br />-11— <br />MODIFIERS: <br />TR OPERATING COIL <br />A COMBINED WITH CIRCUIT NUMBER. <br />EXAMPLE: 10, 4b, ETC, <br />3 <br />200A <br />CLF =CURRENT LIMITING FUSE <br />DE = DUAL ELEMENT <br />ON or OFF DELAY <br />RANGE:SEC MIN <br />TELEPHONE <br />& COMMUNICATION SYSTEMS <br />O MAIN SERVICE METER <br />ID F = CLASS F <br />SET:SEC/MIN <br />I <br />SUBSCRIPT MODIFIER INDICATES: <br />FUSE WITH <br />FU BLOWN INDICATOR <br />2 = DOUBLE POLE <br />UNLESS OTHERWISE SPECIFIED, TELEPHONE <br />O O <br />PUSHBUTTON, MOMENTARY CONTACT, <br />3 = THREE WAY <br />OUTLETS SHALL BE MOUNTED AT SAME HEIGHT <br />DESCPTN <br />NORMALLY OPEN <br />NORMALLY NORMALLY <br />OPEN CLOSE <br />4 = FOUR WAY <br />AS THE RECEPTACLES, <br />VERIFY. <br />MF MULTI -FUNCTION ELECTRONIC METER <br />ID2TR <br />2TR <br />K = KEY OPERATED <br />= <br />MC MOMENTARY CONTACT, THREE <br />EXTERNAL LINE OR PLANT PHONE <br />O 1 O <br />PUSHBUTTON, MOMENTARY CONTACT, <br />NORMALLY CLOSED <br />O OR p-� OR DELAY ON COIL <br />ZA <br />POSITION <br />® <br />SYSTEM OUTLET <br />DESCPTN <br />T (ON D <br />TC /� TO (ON DELAY) <br />MS = MANUAL (MOTOR) STARTER OR <br />MODIFIERS: <br />ID <br />SWITCH <br />T <br />TELEPHONE <br />OHO <br />R = RHEOSTAT (DIMMER, SPEED <br />STOP PUSHBUTTON WITH LOCKOUT�O <br />POSITION (LIMIT) <br />CONTROL) <br />SWITCH <br />DESCPTN <br />RECEPTACLES: <br />GROUNDING <br />GENERAL NOTES <br />IDDTEMPERATURE <br />SWITCH <br />UNLESS OTHERWISE SPECIFIED, ALL RECEPTACLES <br />O <br />ARE 125 VOLT, SINGLE PHASE, STRAIGHT BLADE, <br />H A <br />NON LOCKING, GROUNDING STYLE. <br />O <br />GROUND ROD <br />1. THIS DRAWING IS GENERAL IN NATURE. SOME SYMBOLS SHOWN HEREON MAY NOT BE <br />�O PRESSURE <br />USED ON THE CONTRACT DRAWINGS. <br />SWITCH <br />DUPLEX RECEPTACLE, 20 AMP, <br />® <br />GROUND ROD WITH GROUND WELL <br />2. IDENTIFICATIONS (ID), SIZES, RATINGS, LOCATIONS AND SIMILAR INFORMATION SHOWN <br />SELECTOR SWITCH <br />VJ1 3 WIRE <br />ASSOCIATED WITH SYMBOLS ARE OPTIONAL; EXAMPLES OF SUCH INFORMATION ARE <br />3 POSITION MAINTAINED CONTACT <br />■ <br />GROUND CONNECTION, BOLTED TYPE <br />SHOWN WITH SOME SYMBOLS FOR CLARITY. <br />X = CONTACTS CLOSED <br />RECEPTACLE MODIFIERS: <br />3. THE ELECTRICAL DRAWINGS USE THE ONE -LINE DIAGRAMS AND PANEL SCHEDULES IN <br />GROUND CONNECTION, COMPRESSION <br />CONJUNCTION WITH SHOWING THE LOCATION OF THE ELECTRICAL/INSTRUMENTATION <br />L = LENS COLOR: <br />WP =WEATHER PROOF <br />TYPE <br />SOURCES AND LOADS/DEVICES SHOWN ON THE PLAN DRAWINGS TO DEPICT THE WORK. <br />A = AMBER <br />GF = GROUND FAULT CIRCUIT <br />INTERRUPTER <br />THE CONTRACTOR SHALL USE THESE DOCUMENTS TO DETERMINE AND PROVIDE THE <br />NECESSARY RACEWAY AND WIRING SYSTEM FOR EACH CIRCUIT. ALL INDOOR RACEWAY <br />B = BLUE <br />H = HAZARDOUS AREA- <br />G <br />GROUNDING CONDUCTOR, MINIMUM <br />SHALL BE RUN EXPOSED, AND ROUTED BY THE CONTRACTOR, UNLESS OTHERWISE <br />EN <br />- EXPLOSION PROOF <br />N2/0 BARE COPPER <br />NOTED . THE TYPE OF RACEWAY AND WIRE USED SHALL BE AS SPECIFIED IN THE <br />R = RED <br />UNLESS OTHERWISE NOTED. <br />LINE <br />W = WHITE <br />DOUBLE DUPLEX RECEPTACLE, <br />4. THE LOCATION OF THE CONTROL STATIONS SHOWN ON THE PLAN DRAWINGS ARE <br />ySPECIFICATIONS <br />y <br />INSTRUMENT CABLE SHIELD GROUND <br />DIAGRAMMATIC AND THE ACTUAL LOCATION SHALL BE COORDINATED IN THE FIELD WITH <br />L <br />INDICATING LIGHT <br />THE OWNER. <br />PUSH TO TEST, TEST <br />_ <br />LEGEND <br />VOLTAGE TERMINAL SHOWN <br />5. THE EXACT LOCATION OF THE MOTORS AND ACCESSORIES ARE NOT SHOWN. THE <br />CONTRACTOR SHALL COORDINATE AND REFER TO OTHER DRAWINGS FOR CONDUIT <br />STUBOUT AND TERMINATION LOCATIONS. <br />6. ALL EQUIPMENT SHALL BE LABELED WITH NAMEPLATES. DESCRIPTION OF EQUIPMENT <br />STANDARD ABBREVIATIONS <br />LIGHTING <br />CIRCUITS AND RACEWAYS <br />MISCELLANEOUS <br />SHALL BE IN ACCORDANCE WITH THE ONE -LINE DIAGRAM DESCRIPTION. A LIST OF THE <br />NAMEPLATES SHALL BE SUBMITTED TO THE CONSTRUCTION MANAGER PRIOR TO <br />ENGRAVING. <br />FIXTURE IDENTIFIER: <br />Alt OVERHEAD POWER LINES <br />7. UNLESS OTHERWISE NOTED, ALL CONVENIENCE OUTLETS SHALL BE MOUNTED AT <br />A <br />ATS <br />AMMETER <br />AUTOMATIC TRANSFER SWITCH <br />- RACEWAY IN CONCRETE <br />r <br />TYPICAL DETAIL DESIGNATION <br />48 -INCHES ABOVE FINISHED FLOOR. ALL LIGHT SWITCHES SHALL BE MOUNTED AT <br />BCW <br />BARE COPPER WIRE <br />NUMBER OF FIXTURES (SHOWN <br />hP E-7 <br />54 -INCHES ABOVE FINISHED FLOOR. <br />C <br />CONDUIT <br />ONLY WHEN REQUIRED FOR <br />CLARITY) <br />RACEWAY CONCEALED (UNDERGROUND) <br />B. EACH CONVENIENCE OUTLET AND LIGHTING CIRCUIT SHALL BE PROVIDED WITH A #12AWG <br />C.O. <br />CP <br />CONDUIT ONLY (EMPTY CONDUIT) <br />CONTROL PANEL <br />.1 <br />GROUND CONNECTION <br />GREEN GROUNDING CONDUCTOR <br />CPT <br />CS <br />CONTROL POWER TRANSFORMER <br />CONTROL SWITCH <br />FIXTURE TYPE REFER TO FIXTURE <br />SCHEDULE TYPE APPLIES TO ALL <br />RACEWAY TURNED TOWARD <br />THE VIEWER, <br />PROGRAMMABLE LOGIC <br />9. IN GENERAL, LANDFILL SITE IS CONSIDERED AS CLASSIFIED HAZARDOUS LOCATION. ALL <br />CONDUITS ENTERING OR LEAVING UNDERGROUND SHALL BE PROVIDED WITH "EYS" SEALS <br />CT <br />CONTACTOR (HEAVY DUTY) <br />FIXTURES OF THE SAME SHAPE <br />CONTROLLER 0 <br />/ <br />FILLED WITH COMPOUND RECOMMENDED BY SEAL MANUFACTURER AFTER CONDUCTORS <br />FS <br />FLOAT SWITCH <br />WITHIN A ROOM OR AREA. <br />RACEWAY TURNED DOWN <br />ARE INSTALLED. <br />Q <br />HZ <br />GROUND <br />HERTZ <br />OT <br />THERMOSTAT <br />KVAR <br />REACTIVE POWER <br />R MOUNTING: <br />EXPOSED RACEWAY <br />KW <br />KILOWATT <br />XX <br />KWHR <br />KLOWATTHOUR <br />C = CEILING R = RECESSED <br />HH23 <br />O <br />NOTE DESIGNATION <br />1/0 <br />INPUT/OUTPUT2/40 <br />8,-6 PP = POLE S = STANCHIONEl <br />MANHOLE (MH) OR HANDHOLE (HH), <br />LOS <br />MCC <br />MCP <br />LOCKOUT STOP <br />MOTOR CONTROL CENTER <br />MOTOR CIRCUIT PROTECTOR <br />\ P = PENDANT W = WALL <br />JUNCTION <br />DESIGNATES EQUIPMENT OR <br />DEVICE LOCATED AT LOAD <br />IN THE FIELD <br />Underground Service Alert <br />Call: TOLL FREE <br />MF <br />MULTI -FUNCTION METER DISPLAY <br />MOUNTING HEIGHT, FLOOR TO <br />BOX. <br />O <br />MIN <br />MINK <br />MINIMUM <br />MAIN SWITCHGEAR <br />BOTTOM FIXTURE UON. <br />TB TERMINAL BOX. <br />❑ <br />'� <br />DESIGNATES EQUIPMENT OR <br />1-800 <br />i, 227-2600 <br />NC <br />NORMALLY CLOSED <br />A <br />AHAP = AS HIGH AS POSSIBLE. <br />DEVICES LOCATED IN MCC <br />NIC <br />NOT IN CONTRACT <br />vM <br />ecroRE rou DIG <br />NO <br />NORMALLY OPEN <br />3#10 AWG <br />DESIGNATES EQUIPMENT OR <br />PAIR OR PR <br />TWISTED, SHIELDED PAIRS <br />NUMBER OF LAMPS/LAMP WATTAGE <br />DEVICES LOCATED IN <br />IF SHEET IS LESS THAN 24" BY 36", THEN IT IS A REDUCED PRINT -SCALE <br />REDUCED ACCORDINGLY. <br />PBPULL <br />BOX <br />+ #10 AWG G, 1"C <br />CONTROL PANEL <br />PLC <br />PROGRAMMABLE LOGIC CONTROLLER <br />LIGHTING FIXTURE SHAPES AND SCALE ARE <br />RACEWAY SIZE WITH CONDUCTOR <br />pp <br />POWER POLE <br />REPRESENTED WHERE POSSIBLE. THE <br />CONTENTS AND SIZES. <br />PUMP CONTROLLER'S <br />OH <br />OVERHEAD <br />EXAMPLES SHOWN BELOW ARE TYPICAL <br />DISCRETE OUTPUT <br />REV DATE DescRlPnoN <br />DRN APP <br />RTD <br />RTU <br />SCADA <br />RESISTANCE THERMAL DETECTOR <br />REMOTE TERMINAL UNIT <br />SUPERVISORY CONTROL & DATA ACQUISITION <br />APPLICATIONS <br />LP -1 <br />CIRCUIT HOMERU1 W/ DESTINATION <br />NOTED (212, X12 GND MIN.) <br />® <br />IONIZATION SMOKE DETECTORGeosyntecDSSRS <br />*ukm; <br />SOLID STATE REDUCED VOLTAGE STARTER <br />ENGINEER$, LNG.SWGR <br />SWITCHGEAR <br />FLUORESCENT FIXTURE <br />/ TELEPHONE SYSTEM CONDUIT <br />consultants Oakland, San Francisco, Orange County, CA <br />THD <br />HARMONIC DISTORTION <br />T <br />E <br />END -OF -LINE DEVICE <br />TS <br />TEMPERATURE SWITCH <br />/ WITH PULLING NYLON ROPE <br />1111 BROADWAY, 6TH fly 1611 TELEGRAPH ABENUE, SUITE 809 <br />OAKLAND, CA 94807 OAKLAND, CA 99612 <br />1810 EAST HAZELTON AVENUE <br />STOCKTON, CA 95205 <br />\I <br />VFD <br />WP <br />VOLTMETER <br />VARIABLE FREQUENCY DRIVE <br />WEATHER PROOF (NEMA 4X) <br />I --O I -O WALL MOUNTED FIXTURE <br />LIGHT CIRCUIT W/ CONDUCTOR <br />QUANTITY INDICATED <br />❑F <br />FIRE ALARM PULLSTATION <br />PHONE: 510.836.3034 PH E. 510.267.0441 <br />TITLE: <br />PHONE: 209.468.3000 <br />XFMR <br />TRANSFORMER <br />ELECTRICAL LEGEND AND GENERAL <br />NOTES <br />FVNV <br />FULL VOLTAGE NON -REVERSING STARTER <br />(Y� (y� <br />MDP-4XX DESIGNATES 480V CIRCUIT <br />� <br />COMBINATION STROBE LIGHT/HORN <br />PROJECT: <br />EMERGENCY LIGHTING UNIT. <br />PS -21 XX DESIGNATES 21KV CIRCUITFIREALARM <br />CONSTRUCTION OF AREA 2A <br />lul SELF CONTAINED. <br />CONTROL PANEL <br />xLrLE <br />SPACE HEATER <br />5TEi FOOTHILL SANITARY LANDFILL <br />SAN JOAQUIN COUNTY, CALIFORNIA <br />THIS DRAWING MAY NOT BE ISSUEDQ\LGFES$/Q DESIGN BY: TP <br />EOR PROJECT TENDER OR p.p <br />DATE: NOVEMBER 2014 <br />TAN N(�'�k/� <br />CONSTRUCTION, UNLESS SEALED, H O vy��YLg DRAWN BY: LD <br />11��A <br />PROJECT NO.: WG1780 <br />It" W117 <br />CHECKED BY: DN <br />EYy. B 5 <br />FILE: WG1780-E001 <br />"tuR£ REVIEWED BY: DTN <br />DRAWING NO.: E-1 <br />SOF (,AUY"" APPROVED BY: DTN <br />14 25 <br />GA. <br />OF <br />