Laserfiche WebLink
GSE <br />ENV IRON ME NTAC" Quality Assurance Laboratory Test Results <br />Project: GBE Foothills Landfill <br />Sales Order: 75851 <br />Product: BLI-075-06N-06W-D-40 Bentol-iner NWL <br />Required Testing: ASTM D5887 - Standard Test Method for Measurement of Index Flux Through <br />Saturated Geosynthetic Clay Liner Specimens Using a Flexible Wall Permeameter <br />Frequency: <br />1/250,OOOsf, 1/Bentonite Lot <br />Effective Stress: <br />5 psi <br />Index <br />Hydraulic <br />Flux <br />Conductivity <br />Bentonite Lot <br />Roll Number <br />Production Date <br />(m'/m2/sec) <br />(cm/sec) <br />1050515 <br />502252244 <br />5/12/2015 <br />4.72E-09 <br />1.90E-09 <br />1050715 <br />502252356 <br />5/13/2015 <br />2.69E-09 <br />1.09E-09 <br />1051315 <br />502252657 <br />5/18/2015 <br />3.87E-09 <br />1.66E-09 <br />1050815 <br />502252422 <br />5/14/2015 <br />5.86E-09 <br />1.90E-09 <br />1051115 <br />502252625 <br />5/15/2015 <br />6.23E-09 <br />2.45E-09 <br />1051515 <br />502252754 <br />5/20/2015 <br />3.65E-09 <br />1.31E-09 <br />... :. <br />�. - ';�♦ a -s t <br />GSE 8.2.4-037 <br />0 Rev 02 06/07/12 <br />Report Date <br />6/3/2015 <br />