Laserfiche WebLink
TESTING, RESEARCH, CONSULTING AND FIELD SERVICES <br />A.u_'N, TX - USA I ANAHEIM, CA - USA I ANCER90N, SC - USA I Cato COAST - AUST A I SUEHOU - CHINA <br />June 1, 2015 <br />Kris Khilnani <br />Advanced Earth Sciences <br />9307 Research Drive <br />Irvine, CA 92618 Initial: eve 9:0.18 <br />DATE: 06/01/2015 <br />Re: FINAL LABORATORY TEST REPORT <br />Dear Mr. Khilnani: <br />Thank you for consulting TRI California for your material testing needs. <br />Enclosed is the final laboratory report for the Conformance testing of three (3) Bentoliner NWL-45 GCL samples <br />PROJECT NAME: Foothills Area 2A <br />DATE REPORTED: June 1, 2015 <br />REFERENCE TRI JOB NO.: G150364 <br />DATE RECEIVED: May 18, 2015 <br />SAMPLED BY: TRI -CA at GSE, SD <br />SAMPLE IDENTIFICATIONS: <br />SAMPLED <br />TRI CONTROL NUMBER <br />1. R#502252383 L#25051311 <br />103993 <br />2. R#502252344 L#25051311 <br />103994 <br />3. R#502252422 L#25051411 <br />103995 <br />TESTS REQUIRED / PERFORMED: <br />TEST METHOD <br />DESCRIPTION <br />1. ASTM D4632 <br />Peel Strength <br />2. ASTM D5993 <br />Mass Per Unit Area <br />3. ASTM D5084 <br />Hydraulic Conductivity <br />4. ASTM D5887 <br />Index Flux <br />TEST RESULTS: The test results are summarized in the attached Tables 1 to 3. <br />Respectfully, <br />TRI Environmental, Inc. - California <br />° <br />anent ° <br />Maria Espitia <br />Carmelo V. Zantua <br />Quality Assurance <br />Technical Director <br />sigrrolu ere on file <br />It shall be noted that the samples tested we believed to be true representatives of the material produced under the designation herein staled. In addition, the attached <br />laboratory tests results are considered indicative only of the quality of samples/spechris s that were actually tested. The appropriate fest methods hereby employed are based <br />on the current and accepted industry practices. TRI neither accepts responsibility for nor makes claims to the intended final use and purpose of the material. The test data and <br />all associated project information shall be held confidential and not to be reproduced and/or disclosed to other parties encepl in full and with prior wriften approval from pertinent <br />entity duly authorized by the respec,bw client or from the client itself. It is our policy to keep physical records of each job for two (2) years commencing from the dale of receipt of <br />the Samples and keep Its corresponding electronic file to seven (7) years. Retained COn1om18noe samples are disposed of after one (1) month. On the Other hand, should <br />you need us to keep them at a longer period, please advise us in wdfing. <br />4 Pages Total (including this sheet) <br />1160 North Gilbert Street, A elm, CA 92801, www.precisionlabs.net <br />Precision Geosynthetic Laboratornational dba TRI Environmental, Inc. <br />