My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_1999_1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_1999_1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:20 PM
Creation date
7/3/2020 10:47:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
1999_1
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_1999_1.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1129
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE OF CONTENTS <br /> 1.0 INTRODUCTION...................................................................................................1 <br /> 2.0 PROJECT CONSTRUCTION SUMMARY............................................................4 <br /> 3.0 PROJECT CQA DOCUMENTATION....................................................................5 <br /> 4.0 EARTHWORKS CONSTRUCTION.......................................................................6 <br /> 4.1 Earthworks Preconstruction Meeting..........................................................6 <br /> 4.2 Excavation/Fill and Subgrade Foundation Preparation..............................6 <br /> 4.3 Clay Liner...................................................................................................7 <br /> 4.3.1 Processing of Clay Liner Materials ..................................................7 <br /> 4.3.2 Clay Liner Placement ......................................................................8 <br /> 4.4 Leachate Collection and Removal System Drainage Layer.......................9 <br /> 4.5 Operations Layer Protective Soil..............................................................10 <br /> 5.0 GEOSYNTHETICS CONSTRUCTION................................................................11 <br /> 5.1 General Description of Activities ..............................................................11 <br /> 5.2 Geosynthetics Preconstruction Meeting...................................................11 <br /> 5.3 Geosynthetic Clay Liner (GCL) Installation ..............................................11 <br /> 5.3.1 GCL Factory Quality Control..........................................................11 <br /> 5.3.2 GCL Conformance Testing............................................................12 <br /> 5.3.3 GCL Deployment. ........................................................................1 <br /> 5.4 Geomembrane Installation .......................................................................1 <br /> 5.4.1 Geomembrane Factory Quality Control.........................................12 <br /> 5.4.2 Geomembrane Conformance Testing ...........................................13 <br /> 5.4.3 Geomembrane Deployment...........................................................13 <br /> 5.4.4 Geomembrane Test Seams (Trial Start-Up Welds).......................13 <br /> 5.4.5 Geomembrane Field Seaming.......................................................14 <br /> 5.4.6 Geomembrane Nondestructive Seam Testing ..............................14 <br /> 5.4.7 Geomembrane Destructive Seam Testing.....................................15 <br /> 5.4.8 Liner Vents for the Class II Impoundment .....................................16 <br /> 5.4.9 Lysimeters for the Class II Leachate Impoundment ......................16 <br /> 5.4.10 Well Abandonment........................................................................16 <br /> 5.5 Geocomposite Installation...................................................................................16 <br /> 5.5.1 Geocomposite Factory Quality Control..........................................17 <br /> 5.5.2 Geocomposite Deployment ...........................................................17 <br /> 5.6 Geotextile Installation..........................................................................................17 <br /> 5.6.1 Geotextile Factory Quality Control.................................................17 <br /> 5.6.2 Geotextile Deployment..................................................................18 <br /> 5.7 Geonet Installation ..............................................................................................18 <br /> 5.7.1 Geonet Factory Quality Control .....................................................18 <br /> 5.7.2 Geonet Deployment.......................................................................18 <br /> 6.0 CONCLUSION ....................................................................................................20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.