Laserfiche WebLink
The pseudo -static analyses that were completed for the project to evaluate earthquake <br />loading conditions indicate yield accelerations from about 0.10g to 0.11 g for the range <br />of interface shear strength parameters shown in Figure 3. The yield acceleration is the <br />seismic coefficient (k,) that yields a static factor of safety of 1.0. As shown in the <br />attached calculations, using these yield accelerations and Bray & Rathje's method, an <br />insignificant amount of seismic -induced permanent displacement of the landfill liner <br />system is calculated for the two design earthquake events (i.e., Great Valley and San <br />Andreas fault MCE's). <br />4.0 FINAL COVER STABILITY ANALYSES <br />4.1 Anticipated Final Cover Geometry <br />The final cover for the proposed development is a multi -layer system that, from top to <br />bottom, will consist of the following: 1 -foot thick vegetative soil layer; drainage layer; <br />60 -mil thick HDPE geomembrane, textured.on.both sides;...l_-foot.thick compacted.clay <br />layer with maximum permeability of 10-6 cm/sec and; 2- foot thick compacted <br />foundation layer. The proposed final cover,wi11,,have a -s1< ,,gradient of 3:1,�,[+V) <br />between benches that will be installed on 40 -foot vertical intervals. Recognizing that a <br />drainage layer will preclude developm.ent.of,pore-water,pressu.res, the -interface <br />between the vegetative soil layer and the underlying textured HDPE is considered the <br />critical potential failure surface. <br />4.2 Analytical Methods <br />Because the length of cover between benches._(about 126_.feet),is,.significantly.greater <br />than the thickness of the cover system (4 feet), the semi -infinite slope analysis <br />procedure was considered appropriate to evaluate the stability of the ..final cover slope. <br />Slope stability was evaluated for both static and seismic loading conditions. Since <br />..aaboratory tests have not been performed to obtain shear.strength parameters.for.the <br />textured HDPE/vegetative soil interface, the analyses were directed to "back -calculate" <br />.the strength properties that will be required to provide a static factor -of safety_of l._5. <br />This information will then be used to establish minimum criteria for later construction of <br />the final cover. <br />4.3 Final Cover Stability Results <br />As shown in the attached calculations, the results of the semi -infinite slope analyses <br />indicate that a static factor of safety of 1.5 can be obtained for the proposed final cover <br />configuration providing that the interface between textured HDPE and the vegetative <br />layer above it or clay below it develops an angle of friction of 27 degrees with no <br />cohesion (i.e. � = 27° and c= 0). Review of the native soil data generated in the area <br />by CH2MHill (1992) suggests that the required interface strength parameters can be <br />achieved. <br />L:Allied\2000.193\Reports\finaljtd:Appendix E GLA:08/16/01 <br />