Laserfiche WebLink
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * <br />FLOW PROCESS FROM NODE-----1_23-TO NODE 1.09 IS CODE = 1 <br />--------------------------------------------------------------- <br />TOTAL AREA(ACRES) = 24.65 PEAK FLOW RATE(CFS) = <br />57.37 <br />END OF SUBAREA "V" GUTTER HYDRAULICS: <br />DEPTH(FEET) = 2.02 FLOOD WIDTH(FEET) = 8.08 <br />FLOW VELOCITY(FEET/SEC.) = 7.02 DEPTH*VELOCITY = <br />14.21 <br />**************************************************************************** <br />FLOW PROCESS FROM NODE 1.22 TO NODE 1.23 IS CODE <br />= 9 <br />---------------------------------------------------------------------------- <br />>>>>>COMPUTE "V" GUTTER FLOW TRAVEL TIME THRU SUBAREA«« <br />< <br />UPSTREAM NODE ELEVATION(FEET) = 38.00 <br />DOWNSTREAM NODE ELEVATION(FEET) = 34.00 <br />CHANNEL LENGTH THRU SUBAREA(FEET) = 720.00 <br />"V" GUTTER WIDTH(FEET) = .00 GUTTER HIKE(FEET) _ <br />.001 <br />PAVEMENT LIP(FEET) = .001 MANNING'S N = .0150 <br />PAVEMENT CROSSFALL(DECIMAL NOTATION) _ .50000 <br />MAXIMUM DEPTH(FEET) = 5.00 <br />1000 YEAR RAINFALL INTENSITY(INCH/HR) = 2.531 <br />*USER SPECIFIED(SUBAREA): <br />NATURAL OR AGRICULTURE SUBAREA LOSS RATE, Fm(INCH/HR) <br />= .0500 <br />TRAVEL TIME THRU SUBAREA BASED ON VELOCITY(FEET/SEC.) <br />= 7.35 <br />AVERAGE FLOW DEPTH(FEET) = 2.20 FLOOD WIDTH(FEET) <br />= 8.79 <br />"V" GUTTER FLOW TRAVEL TIME(MIN.) = 1.63 TC(MIN.) <br />= 19.17 <br />SUBAREA AREA(ACRES) = 12.19 SUBAREA RUNOFF(CFS) = <br />27.21 <br />EFFECTIVE AREA(ACRES) = 36.84 AVERAGED Fm(INCH/HR) <br />_ .05 <br />TOTAL AREA(ACRES) = 36.84 PEAK FLOW RATE(CFS) = <br />82.25 <br />END OF SUBAREA "V" GUTTER HYDRAULICS: <br />DEPTH(FEET) = 2.34 'FLOOD WIDTH(FEET) = 9.33 <br />FLOW VELOCITY(FEET/SEC.) = 7.55 DEPTH*VELOCITY = <br />17.64 <br />**************************************************************************** <br />FLOW 'PROCESS FROM NODE 1'.23 TO NODE 1.09 IS CODE - 9 <br />---------------------------------------------------------------------------- <br />>>>>>COMPUTE "V" GUTTER FLOW TRAVEL TIME THRU SUBAREA«« <br />< <br />UPSTREAM NODE ELEVATION(FEET) = 34.00 <br />DOWNSTREAM NODE:.ELEVATION(FEET) = 30.00 <br />CHANNEL LENGTH THRU SUBAREA(FEET) = 850.00 <br />"V" GUTTER WIDTH(FEET) = .00 GUTTER HIKE(FEET) _ <br />.001 <br />PAVEMENT -'LIFPIFEET) - . .001 "- MANNING"°S l = :0150 <br />PAVEMENT CROSSFALL(DECIMAL NOTATION) _ .50000 <br />MAXIMUM DEPTH(FEET) = 5.00 <br />1000 YEAR RAINFALL INTENSITY(INCH/HR) = 2.407 <br />*USER SPECIFIED(SUBAREA): <br />NATURAL OR AGRICULTURE SUBAREA LOSS RATE, Fm(INCH/HR) <br />= .0500 <br />TRAVEL TIME THRU SUBAREA BASED ON VELOCITY(FEET/SEC.) <br />= 7.42 <br />AVERAGE FLOW DEPTH(FEET) = 2.53 FLOOD WIDTH(FEET) <br />= 10.11 <br />"V" GUTTER FLOW TRAVEL TIME( -MIN.) = 1-.91 TC(MIN.) <br />= 21.08 <br />SUBAREA AREA(ACRES) = 11.92 SUBAREA RUNOFF(CFS) = <br />25.29 <br />EFFECTIVE AREA(ACRES) = 48.76 AVERAGED Fm(INCH/HR) <br />_ .05 <br />TOTAL AREA(ACRES) = 48.76 PEAK FLOW RATE(CFS) = <br />103.44 <br />END OF SUBAREA "V" GUTTER HYDRAULICS: <br />DEPTH(FEET) = 2.63 FLOOD WIDTH(FEET) = 10.50 <br />FLOW VELOCITY(FEET/SEC.) = 7.50 DEPTH*VELOCITY = <br />19.71 <br />* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * <br />FLOW PROCESS FROM NODE-----1_23-TO NODE 1.09 IS CODE = 1 <br />--------------------------------------------------------------- <br />