My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2001_2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2001_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:22 PM
Creation date
7/3/2020 10:48:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2001_2
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2001_2.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
853
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• Prior to shipment, the Liner Manufacturer shall provide the Construction <br />Manager with a quality control certificate for each roll of geomembrane. The <br />quality control certificate(s) shall be signed by a responsible person employed <br />by the Liner Manufacturer and shall include: <br />— Lot and roll numbers and identification. <br />— Sampling procedures and results of quality control tests. At a minimum, <br />results shall be given for those properties identified in the Project <br />Specifications. <br />— The Geotechnical CQA Officer shall verify that the quality control <br />certificates have been provided at the specified frequency for all rolls, and <br />that each certificate identifies the rolls related to it. <br />— Review the quality control certificates and verify that the certified roll <br />properties meet the specifications. <br />6.2.2 GEOMEMBRANE DELIVERY <br />Prior to delivery, all individual roll manufacturer certifications required by this <br />document and/or the Project Specifications mus t"be received and approved by the <br />Construction Manager. Delivery of any unapproved roll will not be allowed and <br />unapproved rolls will be transported off-site at the Contractors expense. <br />6.2.2.1 Transportation and Handling <br />All transportation and on-site handling of the geomembrane is the responsibility <br />of the Contractor and Liner Subcontractor. <br />The Geotechnical CQA Officer shall observe the handling equipment used on the <br />site and provide comment on whether it poses any risk of damage to the <br />geomembrane: 'The Geotechnical CQA Officer will also observe the"Contractor <br />and Liner Subcontractor personnel's handling of the geomembrane and provide <br />,comment -gin- ,ether -•appropriate --a,re°is being taken. Finally, the -Geotechnical <br />CQA monitor shall verify that all documentation required upon delivery has been <br />received. <br />Upon delivery at the site, the Contractor, Liner Subcontractor and the <br />Geotechnical CQA Monitor shall complete a surface observation of all rolls for <br />defects and damage. This inspection shall be conducted without unrolling rolls <br />unless defects or damage are found or suspected. The Geotechnical CQA Officer <br />shall report the following to the Construction Manager: <br />Rolls, or portions thereof, which should be rejected and removed from the site <br />because they have severe flaws. <br />Rolls which visually include minor repairable flaws. <br />Any damaged rolls shall be rejected and removed from the site or be stored at a <br />location separate from accepted rolls as designated by the Construction Manager. <br />-17- <br />C\2001-048TINAL COV ER_CQA.DOC\08/20/01 <br />Geologic Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.