Laserfiche WebLink
MONITORING AND REPORTING PROGRAM NO. R5-2003-0049 4 <br />FORWARD INC. AND ALLIED INDUSTRIES <br />FOR OPERATION OF <br />FORWARD CLASS II LANDFILL <br />SAN JOAQUIN COUNTY <br />The constituents of concern include all the waste constituents, their reaction <br />products, and hazardous constituents that are reasonably expected to be in or <br />derived from waste contained in the Unit. The constituents of concern for all <br />Units at the facility are those listed in Tables I through IV for the specified <br />monitored medium, and Table VI. The Discharger shall monitor all constituents <br />of concern every five years, or more frequently as required in accordance with a <br />Corrective Action Program. <br />a. Monitoring Parameters <br />Monitoring parameters are constituents of concern that are the waste <br />constituents, reaction products, hazardous constituents, and physical <br />parameters that provide a reliable indication of a release from a Unit. The <br />monitoring parameters for all Units are those listed in Tables I through V <br />for the specified monitored medium. <br />3. Concentration Limits <br />For a naturally occurring constituent of concern, the concentration limit for each <br />constituent of concern shall be determined as follows: <br />a. By calculation in accordance with a statistical method pursuant to §20415 <br />of Title 27; or <br />b. By an alternate statistical method acceptable to the Executive Officer in <br />accordance with §20415 of Title 27. <br />Concentration limits for detection monitoring have previously been established at <br />old Forward landfill on an intrawell basis and at Austin Road Landfill on an <br />interwell basis. A corrective action evaluation procedure has been adopted for <br />Austin Road Landfill (see Evaluation Procedures for Proposed Corrective Action <br />at Austin Road Landfill). The physical separation between old Forward and <br />Austin Road units means that monitoring results from the two areas can be <br />evaluated independently. Detection and evaluation monitoring programs should <br />continue under the existing protocols. All monitoring results for both areas <br />should be submitted in a single integrated monitor report. <br />Intra -well concentration limits at Forward wells are calculated in the Revised Post <br />Closure Maintenance Plan (November 4, 1994) by Kleinfelder. Parametric or <br />non -parametric tolerance limits with a 95% confidence factor. These confidence <br />limits will continue to be used at the Forward detection monitor wells. <br />Inter -well concentration limits used at Austin Road landfill detection monitor <br />wells are summarized as follows: <br />