PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
953
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Conditions for N-339-17-10 (continued) <br />Page 7 of 9 <br />*75. The enclosed flare shall be equipped with either a device that records flow to the control device. The owner or <br />operator shall install, calibrate:, and maintain a gas flow Tato measuring device that shalt revord the flow to the control <br />device at least every 15 minutes. [40 CTR 60.756(b)(2)] Federally Enforceable I'trrough 'title V Permit <br />76. Operator shall measure the gauge pressure in the gas collection header on a monthly basis as provided in § <br />60.755(ax3): and monitor nitrogen or oxygen concentration in the landfill gas on a monthly basis as provided in § <br />60.755(a)(5); and monitor temperature of the landfill gas on a monthly basis as provided in 6 60.755(x)(5). [40 CFR <br />60.756(a)j Federally Enforceable Through Titic V Permit <br />77. Any closed landfill that has no monitored exceedances of the operational standard in three consecutive quarterly <br />monitoring periods may skip to annual monitoring. Any methane reading of 500 ppm or more almve background <br />detected during the annual monitoring returns the frequency for that landfill to quarterly monitoring. (40 CFR <br />60.756(f)j Federally Enforceable Through Title V Permit <br />78, Hach owner or operator shall keep for at least 5 years up-to-date, readily accessible, on-site records of the maximum <br />design capacity, the current amount of solid waste in -plane, and the ytsr-by-year waste acceptance rate. Off-site <br />records may be maintaincd if they are retrievable within 4 hours. [4Q CFR 60.758(a) and District Rule 2520, 9.4.2] <br />Federally Enforccabic Through Titic V Permit <br />19. The initial annual report shall be submitted within 180 drys of installation and start-up of the collection and control <br />system, and shall include the initial performance test report required under 40 CFK 60.8. The initial report shall <br />include information specified in 40 C:l•-R 60.757(8)(1-6). [40 CFR 60.757(f), (g)] l'cdcrdlly Enforceable Through Title <br />V Permit <br />80. The following constitute exceedances that shall be recorded and reported under 40 CPR 60.757(f): all 3 -hour periods <br />of operation during which the average combustion temperature was more than 28 °C below the average combustion <br />temperdturc enuring the most recent performance test (flare source test). 140 CFR 60.758(c)) Federally Enforceable <br />Through Title V Permit <br />81. Except its provided in 60.752(b)(2)(i)(B), each owner or operator of a controlled landfill shall keep tip -to -date, readily <br />accessible records for the life of the control equipment of the data listed in paragraphs 60.758(b)(1) through (b)(4) as <br />measured during the initial performance test or compliance determination. Records of subsequent tests or monitoring <br />shall be maintained for a minimum of 5 years. Records of the control device vendor specifications shall be maintained <br />until removal. [40 CFR 60.758(b)) Federally Enforceable Through Title V Pcrmit <br />82. Pennittee shall keep the following records: (1)(i) the maximum expected gas generation flow rate as calculated in <br />60.755(a)(I ). The Owner or operator may use another method to deteminc the maximum gas generation flow rate, if <br />the method has been approved by the APCO; (ii) the density of wells, horizontal collectors, surface collectors, or other <br />gas extracion devices determined using the procedures specified in 60.759(a)(1); (2)(i) the average combustion <br />temperature measured at least every 15 minutes and averaged over the some bine period of the performance test; (ii) <br />ilia percent reduction of NMOC determined as specified in 60.752(b)(2xii)(B) achieved by the control device. [40 <br />CFR 60.758(b)(1) and (2)] Federally Enforceable Through Title V Permit <br />83. Pernittec shall keep up-to-4atc, readily accessible continuous records of the indication of flow to the enclosed flare. <br />[40 CFR 60.758(c)) Federally Enforceable "Through Title V Permit <br />84. Except as provided in 60.752(b)(2)(i)(B), permittee shall keep, for the; life of the collection system, an up-to-date, <br />readily accessible plot map showing each existing awl planned collector in the system and providing a unique <br />identification location label for each collector. Pennittee shall keep readily accessible documentation of the nature, <br />date of deposition, amount, and location of asbestos -containing or tiondcgradablc waste excluded from collection as <br />well as any nonproductive areas excluded from collection. 140 CFR 60.758(d)] Federally Enforceable Through Title V <br />Permit <br />85. Except ac provided in 60.752(b)(2)(i)(H), pernittee shall keep for at least 5 yeais up-to-date, readily ac cussible records <br />of all collection and control system execcdanccs of the operational standards in 60.753, the reading in the subsequent <br />month whether or not the second reading is an excecdancc, and the location of each excoulanec. [40 CM 60.758(c)] <br />Federally Enforceable Through Title V Pennit <br />,„,,.N „„1. , ��M_�ar CONDITIONS CONTINUE ON NEXT PAGE <br />