My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2002_3 JTD
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2002_3 JTD
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2023 12:53:01 PM
Creation date
7/3/2020 10:49:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2002_3 JTD
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2002_3.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
265
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5.3.2.3 GROSS STABILITY RESULTS <br /> As shown in Appendix E, the results of the stability analyses indicate that a static <br /> factor-of-safety of 1.5 or more can be achieved for the planned landfill geometry <br /> using a range of liner interface shear strength values (Figure 3). <br /> The pseudo-static analyses that were completed for the project to evaluate <br /> earthquake loading conditions indicate yield accelerations from about 0.10g to <br /> 0.11 g for the range of interface shear strength parameters shown in Figure 3. <br /> The yield acceleration is the seismic coefficient (k,) that yields a static factor of <br /> safety of 1.0. As shown in the calculations included in Appendix E, using these <br /> yield accelerations and the Bray & Rathje method (1998), an insignificant amount <br /> of seismic-induced permanent displacement of the landfill liner system is <br /> calculated for the two design earthquake events (i.e., Great Valley and San <br /> Andreas fault MCE's). <br /> 5.3.3 FINAL COVER SLOPE STABILITY <br /> The final cover for the proposed development is anticipated to be a multi-layer <br /> system that, from top to bottom, will consist of the following: 1-foot thick <br /> vegetative soil layer; drainage layer; 60-mil thick HDPE geomembrane, textured <br /> on both sides; 1-foot thick compacted clay layer with maximum permeability of <br /> 10-6 cm/sec and; 2- foot thick compacted foundation layer. The proposed final <br /> cover will have a slope gradient of 3:1 (H:V) between benches that will be <br /> installed on 40-foot vertical intervals. Recognizing that a drainage layer will <br /> preclude development of pore-water pressures, the interface between the <br /> vegetative soil layer and the underlying textured HDPE is considered the critical <br /> potential failure surface. <br /> 5.3.3.1 ANALYTICAL METHODS <br /> As shown in Appendix E, the semi-infinite slope analysis procedure was used to <br /> evaluate the stability of the final cover slope. Slope stability was evaluated for <br /> both static and seismic loading conditions. Since laboratory tests have not been <br /> performed to obtain shear strength parameters for the textured HDPE/vegetative <br /> soil interface, the analyses were directed to "back-calculate" the strength <br /> Forward Landfill JTD 5-16 <br /> L\Allied\2000.7 93\Reports\JTD-PCPCMP702 Sec-5.0:5/24/02 <br /> Revision 1:07/16/02 <br />
The URL can be used to link to this page