Laserfiche WebLink
STATIC AND SEISMIC STABILITY ANALYSIS <br /> WMU FU-03,FORWARD LANDFILL <br /> PROBLEM: <br /> Assess the static and seismic stability of the refuse over the base and side slope lining system for WMU <br /> FU-03 at the Forward,Inc.Landfill. <br /> GIVEN: <br /> These calculations have been previously performed for the prior WMUs at the site and they have been <br /> found to have a satisfactory factor of safety and seismic deformation. The analysis for WMU D-01 is <br /> similar to WMU FU-03 and the summary for this analysis is therefore included for reference. <br /> SUMMARY: <br /> 1. According to the site development and final grading plans for the site, the maximum planned elevation <br /> of refuse for the landfill is 170 ft MSL with 3:1 slopes and 20 ft wide benches every 50 vertical feet. <br /> The 170 ft elevation may only be achieved if waste placement occurs in adjacent waste management <br /> units. <br /> 2. The maximum elevation of refuse in WMU FU-03,prior to the development of adjacent waste <br /> management units, is 80 ft MSL.This elevation is based on 3:1 slopes on the south, east and west. The <br /> north slope is filled against an existing refuse slope. <br /> 3. Development is planned to the east of WMU FU-03. The east-facing slope of WMU FU-03 is <br /> therefore temporary. Waste placement in the adjacent cell to be constructed to the east of WMU FU- <br /> 03 will buttress the east facing WMU FU-03 slope. <br /> STABILITY ANALYSIS SECTIONS AND CRITERIA: <br /> 1. The critical cross section for the stability analysis is under the maximum filling configuration(refuse <br /> fill elevation 170 ft) in the N-S direction. <br /> 2. The acceptable static factor of safety is 1.5 for permanent slopes. For interim slopes, a static factor of <br /> safety of 1.3 is acceptable. <br /> 3. For seismic analyses,acceptable deformations are less than 1-foot. <br /> SUMMARY OF STABILITY ANALYSIS RESULTS <br /> 1. The minimum factor of safety under the maximum fill configuration is 1.7. The critical failure surface <br /> extends from approximately the crest of refuse,through the refuse mass, and then along the base and <br /> slope liner. Both the base liner interfaces(clay/HDPE and cushion geotextile/HDPE)were analyzed <br /> but the cushion geotextile/HDPE condition was found to be more critical Failure surfaces extending <br /> along the base liner and through the interface liner slope were also searched but found to be less <br /> critical. From the seismic analysis, the anticipated amount of deformation is less than 1-inch. <br /> 2. The stability analysis assumes the base liner interface shear strengths between the clay and textured <br /> HDPE are a friction angle of 18 degrees and an apparent cohesion of 0 psf and a friction angle of 10 <br /> degrees and an apparent cohesion of 1,000 psf for normal load ranges from 0 to 6,500 psf and from <br /> 6,500 to 17,000 psf, respectively. The base liner interface strength between the cushion geotextile and <br /> the textured HDPE geomembrane is a friction angle of 15 degrees and zero cohesion. The slope liner <br /> 0 interface shear strengths are assumed to be a friction angle of 12 degrees and an apparent cohesion of 0 <br />