Laserfiche WebLink
TRI/ENVIRONMENTAL, INC. <br />2,1111 "IM E. N A Texas Research Intemational Company <br />GCL TEST RESULTS <br />TRI Client: Vector Engineering, Inc. <br />Project: Forward Landfill <br />Material: Bentofix GCL <br />Sample Identification: 97444 <br />TRI Log #: E2161-79-07 <br />1 2 <br />3 4 5 6 <br />7 8 9 10 <br />Bentonite - Mass/Unit Area <br />(ASTM D 5993, result @ 12% M.C.) <br />Bentonite mass/unit area (lbs/ft2) 1.01 1.02 <br />0.99 0.98 1.00 <br />1.00 0.01 <br />Moisture Content 15.0 12.1 <br />15.6 12.4 15.0 <br />1 14.0 1.46 <br />Peel Strength <br />(ASTM D 4632, modified for 180 degree peel of GCL) <br />MD - Peel Strength (lbs) 43 53 <br />55 56 53 48 <br />53 56 52 41 <br />51 5 <br />Hydraulic Conductivity - ASTM D 5084 <br />(5 psi effective stress) <br />Hydraulic Conductivity (cm/sec) <br />2.1 E-09 <br />2.1E-09 <br />MD Machine Direction <br />TD Transverse Direction <br />The testing herein is based upon accepted industry practice as well as the test method listed. Test results reported herein do not apply <br />to samples other than those tested. TRI neither accepts responsibility for nor makes claim as to the final use and purpose of the material. <br />TRI observes and maintains client confidentiality. TRI limits reproduction of this report, except in full, without prior approval of TRI. <br />C7 <br />9063 Bee Caves Road / Austin, Texas 78733 / 512 263 2101 / 512 263 2558 <br />2of3 <br />1.0 min <br />15 min <br />5E-9 max <br />