Laserfiche WebLink
A sample of shredded greenwaste was collected in order to determine the moisture <br /> content of the material. The results of this test are pending at the time of this draft, <br /> but will be included here in the final report. <br /> Treated Auto Shredder Waste <br /> The sloped test plot for TASW was constructed without incident. The layout is <br /> presented on Figure 4, and the results are as follows: <br /> Average thickness: 1.38' <br /> Area of plot: 2,500 square feet <br /> Volume of material: 3,450 cubic feet <br /> Weight of material: 149,380 pounds <br /> Density of material: 43.30 pounds/cubic foot or 1,169.1 pounds/cubic yard <br /> The level deck test plot was also constructed and measured without incident. The <br /> layout is presented on Figure 5, and the results are as follows: <br /> Average thickness: 1.36' <br /> Area of plot: 2,500 square feet <br /> Volume of material: 3,400 cubic feet <br /> Weight of material: 136,060 pounds <br /> Density of material: 40.02 pounds/cubic foot or 1,080.5 pounds/cubic yard <br /> A sample of TASW was collected in order to determine the moisture content of the <br /> material. The results of this test are pending at the time of this draft, but will be <br /> included here in the final report. <br /> Soil Cover <br /> As stated above, a test plot was constructed for soil cover at the request of Keith <br /> Kennedy of the CIWMB. The layout is presented on Figure 6. The plot was <br /> constructed on a level deck, and the results are as follows: <br /> 2-2 <br /> ):\Allied\Forward\2006.0154 ADC Test\ADC Test Report\Draft Final ADC Test Report Sec 2.doc <br />