Laserfiche WebLink
t <br /> Ms. Christina Carbajal. <br /> July 19,2006 <br /> Page 2 <br /> If the methane gas component of LFG is allowed to accumulate in a confined area(i.e., utility <br /> lines,irrigation valve boxes, vaults,basements,wall spaces, etc.)and is exposed to an ignition. <br /> source, it can be explosive at concentrations between 5 and 15 percent by volume. At higher <br /> concentrations, methane gas is flammable. However,the presence of methane gas in site soil does <br /> not mean there is an immediate threat of explosion because flames cannot typically propagate <br /> through soil. <br /> Operation Criteria <br /> The most current Permits to Construct/Operate dated.July 22,2002 and October 8, 2002, issued by <br /> the San Joaquin Valley Unified Air. Pollution Control District (SJVUAPCD)delineates several. <br /> main operational criteria for the subject system. This operational criteria states that flare exit gas <br /> temperature be maintained at a minimum of 1400 degrees Fahrenheit during system operation. In <br /> addition the systems are to be operated to maintain compliance with.SJVUAPCD Title V and Rule <br /> 4642 requirements. <br /> State California Code of Regulations (CCR Title 27)requires that solid waste disposal site <br /> owners/operators implement LFG control or monitoring provisions to ensure that methane gas <br /> concentrations in soil at the property line do not exceed the lower explosive limit(LEL, or 5 <br /> percent by volume) and that interiors of onsite structures do not exceed 1.25 percent methane by <br /> volume in.air. <br /> Gas Testing <br /> Testing for methane gas(the combustible component of LFG), oxygen gas, carbon dioxide gas, <br /> pressure,and temperature was performed using a Landtec Gem-2000 Gas Analyzer or comparable <br /> unit. This instrument measures combustible gas concentrations in air directly on either of two <br /> scales: the first as percent by volume of the lower explosive limit(LEL)of methane gas in air (5 <br /> percent), the second as percent by volume (0 to 100 percent) in.the gas sampled.. Instrument <br /> calibration.forms are attached.to this report. <br /> LFG Monitoring Probes <br /> In accordance with the approved testing schedule,LFG Monitoring Probes(GP) are to be tested <br /> quarterly or when methane gas concentrations detected exceed 5 percent by volume. During this <br /> :reporting period,all perimeter LFG monitoring probes defined as Nos. 9 and 11. through 25 were <br /> tested for the presence of LFG. Results indicated that no methane gas concentrations in excess of <br /> 5 percent by volume were detected at any location tested. SCS will continue to monitor Probe Nos. <br /> GP-9,GP-11 and GP-12 weekly as directed by the client. The next complete quarterly probe <br /> monitoring is due by the end of September 2006. <br />