ARCHIVED REPORTS_2006_21
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2006_21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:25 PM
Creation date
7/3/2020 10:51:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2006_21
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2006_21.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
118
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� r <br /> Ms. Christina Carbajal <br /> June 6, 2006 <br /> Page 3 <br /> up to 12.4 percent by volume (see Table 1). By May 23, 2006, methane gas concentrations <br /> detected at Monitoring Probe Nos. GP-11 and GP-12 had decreased to below the LEL in response <br /> to system adjustments and collection system expansion. SCS will continue to monitor Probe Nos. <br /> GP-9, GP-11 and GP-12 weekly as directed by the client. The next complete quarterly probe <br /> monitoring is due by the end of June 2006. <br /> Also, on May 5, 8, 15 and 23, 2006, SCS performed testing of subsurface evaluation monitoring <br /> point ETGP-09 as requested by the Client(see Table 5). These test results are intended for <br /> evaluation purposes to assist in LFG extraction well adjustments. <br /> Finally, on May 15, 2006, SCS performed monthly monitoring of Temporary Gas Probes, defined <br /> as TGP-O 1 through TGP-39, as directed by the Client. Results of this monitoring indicated that <br /> methane gas concentrations in excess of the LEL were detected at several locations tested (up to <br /> 60.4 percent by volume). However, during their reporting period, SCS has continued to observe a <br /> fluctuating trend in the detected methane gas concentration. Note, that these probes are intended <br /> for evaluation purposes only and are not compliance locations (see Table 1). <br /> On-Site Structure onitoring <br /> In accordance with the approved testing schedule, the interior of the on-site structures are to be <br /> tested quarterly. The next quarterly interior structure monitoring is due by the end of June 2006. <br /> LFG Extraction Well Testing <br /> System adjustments are required whenever an extraction well exhibits an unacceptable change in <br /> methane and/or oxygen gas concentration (which could be due to an overpull or underpull <br /> condition). Overpull occurs when the extraction rate of a particular extraction well exceeds that of <br /> the LFG generation rate within the radius of influence of the well. During this overpull condition, <br /> air can be drawn through the ground surface to the extraction well and then ultimately be injected <br /> into the flare. If an excessive overpull condition is allowed to continue for a long period, a <br /> significant drop in the methane gas content of the LFG and/or a subsurface landfill fire could <br /> occur. <br /> Underpull occurs when the extraction rate of a particular extraction well is less than the generation <br /> rate within the radius of influence of the well. This condition could result in off-site subsurface <br /> LFG migration and/or surface emissions. <br /> Results of monthly testing of LFG extraction wells performed on May 5, 8, 13 and 23, 2006 (see <br /> Table 2) indicate that several extraction wells exhibited an overpull and/or underpull condition. <br /> These conditions are necessary to maintain operational criteria (e.g. maintain a minimum 1400 <br />