Laserfiche WebLink
C7 <br />C7 <br />.n Y! <br />Precision Geosynthetic Laboratories <br />CLIENT: VECTOR ENGINEERING, INC <br />PROJECT: Forward Lf <br />VERIFICATION OF MATERIAL PROPERTIES <br />(PGL Job No. 0 0505) <br />MATERIAL DESCRIPTION: Bentofix NL -35 GCL <br />SAMPLED BY: PGL @ Bentofix Technologies, CANADA <br />DATE RECEIVED: July 06, 2006 <br />SAMPLE IDENTIFICATIONS: <br />SAMPLE ID <br />R#55755 L#26070409 <br />R#55782 L#26070409 <br />TESTS REQUIRED: <br />TEST METHOD <br />ASTM D5084 <br />ASTM D4632 <br />ASTM D5993 <br />DATE REPORTED: July 19, 2006 <br />PRECISION CONTROL NUMBER <br />23770 <br />23771 <br />Hydraulic Conductivity <br />Peel Strength Modified <br />Mass Per Unit Area <br />TEST CONDITIONS: These samples were conditioned for a minimum of one hour in the <br />laboratory at 22 + 2°C (71.6 + 3.6°F) and at 60 + 10% relative humidity prior to test. <br />TEST RESULTS: <br />The tests results are summarized in Tables 1 & 2. The units in which the data is reported are <br />included on these tables. <br />PRECISION GEOSYNTHETIC LABORATORIES <br />Maria Espitia <br />Quality Assurance <br />Cora B. Queja <br />Vice President <br />1160 North Gilbert Street, Anaheim, CA. 92801, Tel# 714-520-9631, Fax# 714-520-9637 <br />