Laserfiche WebLink
Job Name: Allied / Forward & Austen Rd LF Cell FU -06 <br />SO Number: 45173 <br />Test: ASTM D 4595 - Test Method for Tensile Properties of Geotexiles by the Wide <br />Width Method <br />8" x 8" specimen, 4 inch gauge length, 0.4 in/min test speed, Machine Direction <br />Customer Criteria: >720 lbs/ft <br />F51080000S Geocomposite <br />Maximum Tensile Load <br />Roll Number lbs/ft <br />110173754 2,014 <br />C <br />Approved By: Don Cunningham <br />Date Approved: 7/26/2006 <br />The above stated data shall not be reproduced except in full, without the written approval of the laboratory. <br />