Precision Geosynthetic.•• • - <br />CLIENT: VECTOR ENGINEERING, INC <br />PROJECT: Forward Lf <br />VERIFICATION OF MATERIAL PROPERTIES <br />(PGL Job No. 060322) <br />MATERIAL DESCRIPTION: Single Sided Geocomposite <br />SAMPLED BY: PGL @ GSE, TX <br />DATE RECEIVED: August 02, 2006 <br />PTIMNWRI <br />R#110174047 L# CTF610640 <br />Geonet Component <br />ASTM D1777 <br />Gecomposite Component <br />ASTM D904 <br />ASTM D4716 <br />DATE REPORTED: August 09, 2006 <br />PRECISION CONTROL NUMBER <br />21246 <br />Thickness <br />Ply Adhesion <br />Transmissivity <br />TEST CONDITIONS: This sample was conditioned for a minimum of one hour in the laboratory <br />at 22 + 2°C (71.6 + 3.6°F) and at 60 + 10% relative humidity prior to test. <br />TEST RESULTS: <br />The tests results are summarized in Tables 1. The units in which the data is reported are <br />included on this table. <br />PRECISION GEOSYNTHETIC LABORATORIES <br />Initials:M C 013 <br />Date: 8 /9 Io G <br />—_ <br />aril0I a Espitia --- <br />Quality Assurance <br />Cora B. Queja <br />Vice President <br />C7 <br />1160 North Gilbert Street, Anaheim, CA. 92801, Tel# 714-520-9631, Fax# 714-520-9637 <br />