Laserfiche WebLink
or are stored at a location separate from accepted rolls. Geocomposite rolls that do not <br />have proper manufacturer's documentation must also be stored at a separate location, <br />until all documentation has been received and approved. <br />4.4.2 Acceptance Testing <br />Tests. The QA/QC Consultant will ensure that samples are removed and forwarded to the <br />Geosynthetic CQA Laboratory for testing at a frequency of one sample per lot or one per 100,000 sq. <br />ft., whichever is more stringent, to ensure conformance to both the Specifications and the <br />Manufacturers list of guaranteed properties. The material will be sampled at the site by the QA/QC <br />Inspectors or at the manufacturing plant by an independent third party under the direction of the <br />QA/QC Consultant. <br />As a minimum, the following shall be established for the Geocomposite: <br />Geonet Core (measurements shall be taken on the edge of the sample where geotextile <br />and geonet are unbonded): <br />Thickness (ASTM D5199) <br />0 Geocomposite: <br />• Peel Strength (GRI GC7) <br />• Index Transmissivity (ASTM D4716) <br />The QA/QC Manager will review all acceptance test results and report any non-conformance to the <br />Construction Manager and Contractor. <br />Sampling Procedures. Samples will be taken across the entire width of the roll. Unless otherwise <br />specified, samples will be 3 ft (1 m) long by the roll width. The QA/QC Consultant will mark the <br />machine direction on the samples with an arrow. <br />Test Results. The QA/QC Consultant will examine all results from laboratory acceptance testing and <br />will report any nonconformance to the Construction Manager. <br />Acceptance Test Failure. If a Geocomposite acceptance sample does not comply with the minimum <br />requirements of the Specifications, the Geocomposite roll from which the sample was taken will be <br />failed by the QA/QC Consultant, and replaced by the Geocomposite Manufacturer at no additional <br />Page 39 <br />