Laserfiche WebLink
1.0 INTRODUCTION <br /> On <br /> behalf of Forward Inc. (Forward), this report presents water quality monitoring data <br /> generated during the fourth quarter 2007 monitoring period and also presents an annual <br /> summary of the monitoring result for the 2007 monitoring year for the Forward Landfill <br /> in San Joaquin County, California. Monitoring was performed in accordance with <br /> requirements listed in the Central Valley Regional Water Quality Control Board <br /> (RWQCB) Order No. R5-2003-0049. For reporting purposes the water quality <br /> monitoring network consists of two units: the Forward Unit and the Austin Unit. Section <br /> 1 provides a description of the monitoring network, site inspections, and standard <br /> observations; Sections 2 and 3 include discussions of water quality data for the Forward <br /> and Austin Units, respectively. <br /> 1.1 MONITORING NETWORK <br /> The water quality monitoring network at the Forward Unit currently includes 15 <br /> groundwater monitoring wells (five of which are dual depth well pairs), one domestic <br /> well, two surface water monitoring stations, and 17 lysimeters(Figure 1-1). Well <br /> MW-24 was recently constructed in anticipation of the proposed southwesterly expansion <br /> of the landfill. Monitoring wells at the Forward Unit have been constructed to monitor <br /> groundwater at the facility as follows: <br /> Forward Unit Groundwater Monitoring Network <br /> Monitorin Point Monitoring Point I.D. <br /> Groundwater Monitoring MW-22,MW-23R,MW-24 <br /> Wells—Background <br /> Groundwater Monitoring MWAA/B,MW-2A/B,MW-3A/B,MW-10, <br /> Wells—Compliance MW-13A/13,MW-14A/13,MW-15,MW-16,MW-17,MW-18, <br /> MW-19,MW-21 <br /> Domestic Well DW-9690 <br /> Piezometers MW-113,MW-213,MW-313,MW-1313,MW-14B <br /> Surface Water Stations FSW-1,FSW-2 <br /> Lysimeters E-1,E-2,W-1,W-2,LY-A,LY-BG 1,LY-E 1 A,LY-E 1 B,LY-E2A, <br /> LY-E213,LY-POND-N,LY-POND-S,FU-03,D-93A,D-9313, <br /> WMW-D-01,WMW-D-02 <br /> The monitoring network at the Austin Unit currently includes 14 groundwater monitoring <br /> wells, two domestic wells, and two surface water monitoring stations (Figure 1-1). Of <br /> note, wells AMW-5R and AMW-19BR were recently constructed as replacements to <br /> wells AMW-5 and AMW-19B which were recently abandoned. The detection <br /> monitoring program (DMP) wells are used to detect a potential release from the landfill, <br /> while the corrective action program (CAP) wells are used to evaluate changes in water <br /> quality caused by releases from the landfill and by subsequent corrective action <br /> measures. Monitoring points at the Austin Unit have been constructed to monitor the <br /> groundwater/surface water at the facility as follows: <br /> D:\2007-0043\Fo—ardAustin_4QO7.doc <br /> 1 Geologic Associates <br />