meter to sound. This point is usually clearly visible on the probe, If it is not visible it should k� <br /> located by dipping the probe into a water container where the contact'can be cl <br /> early seem, then- 1. <br /> marked. The total-length of the water level meter should correspond with the length of the <br /> measuring tape. In addition, the individual marks on the cable- should correspond with the <br /> correct footage. If the cable does not match the measuring tape then the difference cnf consistent) <br /> should be calculated. as a percentage, (Le 100 foot cable measures IO2 feet = 98"/a}. A11 <br /> measurements with the cable should-then be multiplied by 0.98 to eorr-ect for the error. if the <br /> individual footage marksarc not placed correctly and arc not consistent their deviation, the <br /> instrument should be replaced. <br /> If the water level indicator is constructed of a cable then calibration willbeperfotzned once per <br /> year. If there is a discrepancy, the conversion factor will be marked directly on the instrument <br /> Water level indicators constructed of tape are more subject to stretching and should be calibrated <br /> every 6 months and marked with the appropriate conversion.. <br /> Calxibration data for each instrument will be-recorded-and keptia a.binder at the:office forfeiture_ - <br /> reference, 'Ihe most recent call-bration results will also be recorded in the technicians field notesThcrc . <br /> is no specific form for water level indicator calibration. <br /> —HH Meter <br /> PH is subject to significant variations due to temperature, buffering capacity of the <br /> water, and <br /> instrument drift For this reason pH metersmust be-calibratedbefore and after sampling on each.. <br /> day:and at least once more during the day. To calibrate a pH meter the instrurnent reading is <br /> adjusted to read correctly for solutions with a standard pH. - <br /> Standard solutions are mined fresh, according to package kens,for each sampling event. <br /> Standard solutions or powders for pH 4, 7, and I0 are commercially Available- 1hese standards <br /> .arc FMchased fresh and'discarded after shelf life has cid. Shelf lives vary depending on the <br /> brand of standards used. if pre--prepared solution is used,the expiration daze of the solution will <br /> be noted on the calibration log. <br /> Although different brands of pH meters vary, calibration proccdum are similar for all of them.. <br /> A generalized calibration procedure follows: <br /> l. Turn on the instrument,check the battery,and allow to wam up if accessary;. _- <br /> .23.4838451-FO I%23l0R'325 A-2 July 14,2404 <br /> 2000 xkwtWa,tae. <br />