Laserfiche WebLink
-as little agitation as possibk to reducd potential loss of volatile constituents. Major ions, TDS, <br /> and metals analyses (In non-preserved containers) will be collected nem followed <br /> by be collected in preserved containers. Containers will be filled directly�m samples to <br /> the disposable bailer, <br /> immediately capped,and placed in a temperature-monitored iced chest. Caution win be used not <br /> to overfill bottles containing a preservative. Temperature will be monitored by placing-a <br /> thenuometer in the chest and checking to make sure that there is-sufficient ice in the chest to <br /> maintaina emperature of rwdmatol 4 <br /> . tY . degrees Celsius. The Iaboratary will measure; <br /> doctiinent, and report the temperature of thesample container upon arrival at the laboraxory.. <br /> The analytical Iaboratory places a total of 2 ml of nitric acid in some of the 1 liter bottles to <br /> reduce the pH to below 2. On an annual basis an extra.preserved bottle will be filled with <br /> groundwater and-the pH measured in the bottle, It is'assumed tbat the pH will be-below 2. if it <br /> is not the field technician will add nitric acid in measured amounts until the pH is below 2. This <br /> added quantity of acid will be placed in all the preserved bottles.during the fallowing monitoring <br /> rounds until it is checked again the following-year_;Sample_--pH--will-be_confzated:at.lire-: <br /> laboratory and recorded. Deviations will be documented and reported by the laboratory, <br /> Samples;-to be submitted for metals analysis-will. be filtered in the 5cld- Filtering-Will be <br /> performed using an in line filter mechanism which uses the-pumping process-of the-dedicated ° <br /> pump to draw water through the 4 micron'filter A new filter will be used at each well. The new <br /> filters will have a minimum of one filter volume of groundwater prcssufiz;�d through them to- <br /> reduce adsorption effects_ The actual filtered-sarnpleavdl not be collected-until a minimum of <br /> two filter volumes of groundwater has been passed through -the- filter. For wells without <br /> dedicated pumps, the samples are transferred frum.the bailer,through a filter apparatus, into the <br /> appropriates sample container_ The filter apparatus consists of a pressUre vel,a hand-operated <br /> Pressure pump, and a filter cartridge Water from the bailer is placed in the pressure vessel and <br /> enough air pressure(via the hand pump)is applied to force water through the filter cartridge into <br /> the sample bottles_ The pressure vessel is washed in Alconox, steam cleaned, and xinsed'with <br /> ,deianize d.water between wells_ A new fiber cartridge is used at each well. <br /> Samples willbe labeled with a unique sample identification number, project identWcation <br /> number,sample location,and date and time sampled. Samples will be transported to the contract <br /> laboratory under strict chain-of-custody procedures._ <br /> 23-483849-FO I L23 I OR325 A-9 July 14,2(?O4 <br /> 2000 KkWd&4 lac. <br />