Laserfiche WebLink
3.0 Analysis and Results <br /> Table 1 presents the asbestos test results. Asbestos was not detected at any of the sample <br /> locations TEM Laboratories, Inc. (ATEM)performed the laboratory analysis. Each sample was <br /> analyzed for asbestos by the latest approved revision of NIOSH ASBESTOS by NIOSH Method <br /> 7402. <br /> Using fiber dimensions reported in the ATEM report, the estimated fiber volume of asbestos is <br /> 0.3125 cubic micrometers per Fiber(µm3/Fiber). With this volume and a specific gravity of 3 <br /> for asbestos(as reported in the NIOSH asbestos data sheet, Appendix D),the concentration can <br /> be converted to units of micrograms of asbestos per cubic meter of air(µgsb/m3Ak) and is <br /> reported below in Table 3-1 (Appendix E). <br /> Table -1 <br /> Summary of Asbestos Concentrations <br /> Forward Landfill <br /> Sampling Date: October 1,2008 <br /> yAYe�l -moo 'tart a A� t9S-�;t1�CCa�altAt�l�, ■�+ � �:j� <br /> A(Upwind) 2.0 957 <0.001 I <0.0010 <br /> B (Downwind) 1.8 987 <0.0010 <0.0009 <br /> C (Downwind) 2.2 951 <0.00I I <0.0010 <br /> C dup(Downwind) 2.0 978 <0.0010 <0.0009 <br /> E(Downwind) 1.9 955 <0.0010 <0.0009 <br /> S1Q-Shaw ErMrayra tal,Inc. 3-1 <br />