Laserfiche WebLink
3.3.2 Results of Slope Stability Analyses <br /> A discussion of the results of the slope stability analyses performed for the critical conditions are <br /> presented below. Calculations, output data,and plots are presented in Appendix B. <br /> WMU FU-08 Southern Portion <br /> As shown on the Construction Drawings(Appendix A), WMU FU-08 is directly south of the former <br /> Austin Road Landfill and directly east of WMU FU-06. The southern boundary is offset from the <br /> main access road. The site development plan(BAS,200 1)includes development of future modules to <br /> the east of WMU FU-08. <br /> The slope stability analysis was performed for a Forward Landfill refuse fill elevation of 150-ft with a <br /> 3:1 slope. The critical slope configuration is in the east-west direction. Other sections were <br /> considered but assessed to be less critical. <br /> As indicated in Appendix B, a minimum factor of safety of 1.6 is obtained for a sliding block shear <br /> surface along the base liner and through the refuse in the east-west direction. A factory of safety of <br /> 1.6 is acceptable for the temporary east-west slope. The maximum refuse fill height and slope for <br /> WMU FU-08 should be re-evaluated based on actual CQA direct shear tests results on the base and <br /> slope liner interfaces. Because the east slope of WMU FU-08 is a temporary slope, a seismic <br /> deformation analysis was not performed. <br /> Ank <br /> Ir <br /> WNW FU-08 Northern Portion <br /> The slope stability analysis was performed for a 150-ft refuse fill elevation with a 3:1 slope. The <br /> elevation at the base of the cell ranged from approximately 72 ft to 90 ft and grades at approximately <br /> 3 percent to the south. The critical slope configuration is in the south direction. Other sections were <br /> considered,but assessed to be less critical. <br /> As indicated in Appendix B, a minimum factor of safety of 1.8 is obtained for a sliding block shear <br /> surface along the base liner and through the refuse in the south direction. A factory of safety of 1.8 is <br /> acceptable for this temporary refuse fill configuration. The maximum refuse fill height and slope for <br /> WNW FU-08 should be re-evaluated based on actual CQA direct shear tests results on the base and <br /> slope liner interfaces. Seismic deformation analyses were not performed because this slope <br /> represents an interim condition. <br /> Forward Landfill Final Buildout <br /> As shown on the Construction Drawings (Appendix A), WMU FU-08 is directly south of the former <br /> Austin Road Landfill and directly east of WMU FU-06. The southern boundary is offset from the <br /> main access road. The site development plan(BAS,200 1)includes development of future modules to <br /> the east of WMU FU-08. <br /> The slope stability analysis was performed for a maximum Forward Landfill refuse fill elevation of <br /> 195-ft for a NE to SW section running along the intersection of the south and west facing final refuse <br /> ® fill slopes. The effective slope is approximately 5:1. <br /> WMU FU-08 REPORT 3-7 <br />