Laserfiche WebLink
are generated according to the Rankine theory. <br /> 100 trial surfaces will be generated and analyzed. <br /> 3 boxes specified for generation of central block base <br /> * * * * * DEFAULT SEGMENT LENGTH SELECTED BY XSTABL * * * * * <br /> Length of line segments for active and passive portions of <br /> sliding block is 17.0 ft <br /> Box x-left y-left x-right y-right Width <br /> no. (ft) (ft) (ft) (ft) (ft) <br /> 1 99.0 134.0 100.0 134.0 1.5 <br /> 2 150.0 109.0 151.0 109.0 1.5 <br /> 3 152.0 109.0 900.0 116.5 1.5 <br /> Factors of safety have been calculated by the <br /> * * * * * SIMPLIFIED JANBU METHOD <br /> The 10 most critical of all the failure surfaces examined <br /> are displayed below - the most critical first <br /> Failure surface No. 1 specified by 12 coordinate points <br /> Point x-surf y-surf <br /> No. (ft) (ft) <br /> 1 99.14 135.00 <br /> 2 99.84 134.38 <br /> 3 150.87 108.37 <br /> 4 244.95 110.04 <br /> 5 245.86 110.96 <br /> 6 257.88 122.98 <br /> 7 269.91 135.00 <br /> 8 281.93 147.02 <br /> 9 293.95 159.04 <br /> 10 305.97 171.06 <br /> 11 317.99 183.08 <br /> 12 324.91 190.00 <br /> ** - ** - <br /> Corrected JANBU FOS - 2.085 (Fo factor 1.082) <br /> Failure surface No. 2 specified by 12 coordinate points <br />