Laserfiche WebLink
Forward Landfill <br /> Summary of Slope Stability Analyses for WMU D-01 <br /> The purpose of the evaluation was to verify that the minimum static factor of safety for a <br /> typical East-West refuse fill slope was approximately equal to or greater than 1.5 and that <br /> the seismic deformations for the design earthquake were acceptable. The slip surfaces <br /> evaluated involved the liner system. After determining the various static factors of safety <br /> for various liner strengths, the yield accelerations were also estimated. The yield <br /> accelerations were used to estimate deformations for the design earthquake for the site. <br /> Material Properties <br /> Four materials were modeled: subgrade, base liner system, side slope liner system, and <br /> refuse fill. <br /> For subgrade, the properties assumed were a unit weight of 125 pcf, an internal friction <br /> angle of 20 degrees, and a cohesion of 400 psf Because only slip surfaces involving the <br /> liner system and the refuse were evaluated, the properties assumed for the subgrade do <br /> not affect the results of the analyses. Furthermore, previous slope stability evaluations <br /> for the site evaluated slip surfaces into the foundation materials. .These evaluations <br /> concluded that slip surfaces involving the foundation had higher factors of safety than <br /> movements through the lining system. <br /> For refuse fill, the unit weight assumed was 75 pcf. The internal strength was a friction <br /> angle of 33 degrees and no cohesion (Kavazanjian et al., 1995). <br /> The minimum strength for the base liner system was assumed to be the interface between <br /> the HDPE geomembrane and the compacted clay liner. The minimum strength for the <br /> liner system along the side slopes was assumed to involve either the interface between the <br /> smooth side of the HDPE geomembrane and the geocomposite drain, or the .interface <br /> between the HDPE and the GCL. To arrive at a strength envelope, strength values from <br /> direct shear tests completed in general accordance with ASTM D5321 for previous cells <br /> were plotted and generalized strength envelopes were developed for the Base Lining <br /> System and the Side Slope Lining System. The Base and Side Slope Lining System <br /> strength envelopes are shown of Figures I and 2, respectively. A summary of the <br /> previous test results is provided in Table 1. <br /> Section Details <br /> The proposed liner system for WMU D-01 is shown as Section A on Sheet 4 of the <br /> Construction Drawings for WMU D-01 (attached). The final grading plan. in the area of <br /> WMU D-01 is attached in Figure 3 and the refuse rill plan for WMU D-01 prior to the <br /> construction of future adjacent cells is shown on Figure 4. The excavation plan in the <br /> area of WMU D-01 is attached in Figure 5. The cross section evaluated is shown in <br /> Figure 6. <br />