WMU FU-08 October 2008 <br /> Forward Landfill Project No. 021605.08 <br /> Non-Destructive Seam Continuity Testing: After seaming of the panels was <br /> completed, the Contractor's QC technician and Vector's CQA Monitor inspected the <br /> seams and panels for defects. The QC technician marked defective seams or tears, <br /> holes, non-dispersed resin beads or other defects for repair. The air pressure test <br /> method was used for double wedge-welded seams and the vacuum box for extruded <br /> seams for seam continuity testing. Vector's CQA Monitor observed the non- <br /> destructive seam continuity testing and repairs performed by Comanco to ensure <br /> that the seams were satisfactory. The air pressure test logs for the wedge-welded <br /> seams are presented in the seaming log in Appendix I. <br /> Destructive Seam Testing: General - In addition to non-destructive testing, <br /> destructive samples were obtained at random locations to evaluate seam strength <br /> and integrity. The samples were tested for shear strength and peel strength (ASTM <br /> D6392). <br /> Location and Frequency — Vector's CQA Monitor selected the locations of <br /> q 3' <br /> approximately one sample per 500 linear feet of seam. Within the Central Portion <br /> of WMU FU-08, a total of 51 destructive samples were collected and tested from <br /> approximately 24,439 linear feet of seam, resulting in a frequency of 1 test per 479 <br /> linear feet. Additional destructive samples were obtained if there were failures or if <br /> there was an indication of overheating, contamination, or other adverse conditions. <br /> Sampling Procedure - Comanco cut the samples as directed by Vector's CQA <br /> Monitor. Vector's CQA Monitor observed the cutting and assigned sample numbers, <br /> and reviewed sample information (sample number, seam number, seaming <br /> apparatus, operator identification, location, date, and time welded). Vector's CQA <br /> Monitor recorded the samples collected and sample location on the panel layout <br /> drawing. <br /> Vector Engineering, Inc. • 143E Spring Hill Drive•Grass Valley,CA 95945•(530)272-2448 <br /> -28- <br />