Laserfiche WebLink
MD - MACHINE DIRECTION <br />TO - TRANSVERSE DIRECTION <br />DC#1991 Record#272 <br />WnPrecision Geosynthetic Laboratories <br />TABLE 4. <br />MATERIAL PROPERTIES <br />CLIENT:VECTOR, ENGINEERING <br />Date Received: 8/1/2008 <br />PROJECT: Forward Landfill <br />QC'd By: <br />Date Reported: 8/6/2008 <br />PGL Job No.: G080912 <br />Client Sample ID: R#94881.25 <br />PGL Control No.: 49116 <br />Material Description: 7 oz Non -woven Geotextile <br />-- <br />SPECIMENS <br />Pr0j. <br />METHOD <br />1 2 3 4 <br />DESCRIPTION <br />5 6 7 <br />8 9 <br />10 <br />Avg. <br />5t-d.Dev. <br />min max <br />Specs. <br />ASTM D5261 <br />Mass per Unit Area (oz/ yd .2) <br />Test Specimen Size: 4"x 8" <br />8.0 7.7 8.2 8.0 <br />8.2 <br />8.0 <br />0.2 <br />7.7 8.2 <br />>7 min <br />ASTM D4632 <br />Grab Tensile <br />Test was performed as directed in D463Z dry condition. Instron Tensile Testing Machine with hydraulic action grips and <br />1 in x 2 in rubber faces was used. Maximum load used for testing., 1500 lbs <br />Grab Breaking Load (Ibs) <br />MD 231 226 228 221 <br />226 229 231 <br />236 224 <br />236 <br />229 <br />5 <br />221 236 <br />>160 avg <br />TD 220 221 226 221 <br />206 227 232 <br />226 228 <br />229 <br />223 <br />7 <br />206 232 <br />Apparent Breaking Elongation (percent) <br />MD 87 69 73 70 <br />74 74 74 <br />73 73 <br />77 <br />74 <br />6 <br />69 87 <br />TD 87 90 93 93 <br />87 87 86 <br />89 97 <br />93 <br />90 <br />4 <br />86 97 <br />MD - MACHINE DIRECTION <br />TO - TRANSVERSE DIRECTION <br />DC#1991 Record#272 <br />WnPrecision Geosynthetic Laboratories <br />