My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2009_1
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2009_1
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 3:53:31 PM
Creation date
7/3/2020 10:54:24 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2009_1
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2009_1.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 10 C)'- <br /> 1 Global Presence <br /> Personal Attention <br /> HERST & ASSOCIATES, INC <br /> 1 <br /> Mr.Rick Jaime C L- ' I__ iJ <br /> 1 California Department of Corrections and Rehabilitation J <br /> 7650 S.Newcastle Road/P.O.Box 213004 OU ;, X009 <br /> Stockton,CA 95213-9004 <br /> 1 E vV1RONIVIEN i HEALI <br /> October 29,2009 PER;N-I!T'S ERUICES <br /> 1 Dear Mr.Jaime: <br /> Summary of Northern California Youth Correctional Center Sampling Results <br /> ' September 2009 <br /> On September 11, 2009,sampling was performed at the Northern California Youth Correctional Center <br /> ' (NCYCC) to provide supplemental information regarding volatile organic compound (VOC) <br /> concentrations at Well#1,Well#2,Well#4,and the indoor faucet location(Table 1)included in other <br /> recent sampling events. Sampling was performed by Herst & Associates, Inc. VOC analyses were <br /> 1 performed by BC Laboratories,Inc. <br /> Well #4 (reported to be the primary water supply well for the facility) yielded a tetrachloroethene <br /> 1 concentration well below the federal Maximum Contaminant Limits (MCLS). The September 2009 <br /> tetrachloroethene concentration at Well #4 was reported at 3.6 µg/1 compared to an MCL of 5 µg/1. <br /> Trichloroethene was detected at Well#4 at a concentration of 0.62µg/1 compared to an MCL of 5 gg/I. <br /> ' Well #1 (now reported to be a supplemental water supply well that operates about 20% of the year <br /> during peak demand periods) exhibited a tetrachloroethane concentration below the MCL. The <br /> September 2009 tetrachloroethene concentration at Well #1 was reported at 4.7 µg/1 compared to an <br /> 1 MCL of 5 µg/1. Trichloroethene was detected at Well#1 at a concentration of 0.76µg/1 compared to an <br /> MCL of 5 µg/1. <br /> ' Well#2(now reported to be utilized only during short term emergencies, should they occur)exhibited <br /> a tetrachloroethene concentration below the MCL. The September 2009 tetrachloroethene <br /> concentration at Well#2 was reported at 3.5 gg/1 compared to an MCL of 5 µg/1. Trichloroethene was <br /> detected at 0.63 µg/1 compared to an MCL of 5 µg/1. <br /> In September 2009, the indoor faucet sample yielded a tetrachloroethene concentration of 4.6 µg/1 <br /> ' compared to an MCL of 5 µg/1, and trichloroethene was detected at a concentration of 0.71 µg/1 <br /> compared to an MCL of 5µg/1. <br /> Quality assurance samples collected during the September 2009 sampling event included a field blank <br /> 1 at Well #4, a field blank at the indoor faucet, a trip blank, and duplicate samples at Well #4 and the <br /> indoor faucet. The field blank sample at Well #4 was collected to provide an indication of VOCs <br /> present in the ambient outdoor air or the laboratory analytical process. The field blank sample at the <br /> ' indoor faucet location was collected to provide an indication of VOCs present in the ambient indoor air <br /> or the laboratory analytical process. The trip blank sample was collected to provide an indication of <br /> 1 4630 South Highway 94—North Outer Road Telephone(636)939-9111 <br /> St.Charles,Missouri 63304 Fax(636)939-9757 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.