Laserfiche WebLink
Laboratories Inc. <br /> C <br /> Laboratories <br /> Testing Laboratory Since 1949 <br /> Enitltrtt��g Laboratory 1949 <br /> Herst Associates Project: NCYC Reported: 12/15/2008 14:52 <br /> 4630 South Highway 94 North Outer Road Project Number: [none] <br /> Saint Charles, MO 63304 Project Manager: David Vasbinder <br /> Volatile Organic Analysis (EPA Method 8260) <br /> BCL Sample ID: 0816327-01 Client Sample Name: FB@Indoor Faucet, 12/9/2008—7.27:OOAM,David Vasbinder <br /> prop Run Instru- QC MB Lab <br /> Constituent Result Units POL MDL Method Date Datefrime, Anat merit ID DIIVon Batch ID Bias Quals <br /> t-Butyl alcohol <10 ug/L 10 EPA-8260 12112/08 12/12108 14:42 mwb HPCHEM 1 BRL0867 NO <br /> Carbon disulfide ug/L 1.0 EPA-8260 12/12/08 12112f08 14:42 mwb HPCHEM 1 BRL0867 NO <br /> trans-1,4-Dichloro-2-butene <5.0 ugill- 5.0 EPA-8260 12112/08 12/12108 14:42 mwb HPCHEM 1 BRL0867 NO <br /> Diisopropyl ether <0.50 uglI. 0.50 EPA-8260 12/12/08 12/12108 14:42 mwb HPCHEM 1 BRL0867 NO <br /> Ethanol <250 uglL 250 EPA-8260 12/12[08 12/12/08 14-42 mwb HPCHEM I BRL0867 NO <br /> Ethyl t-butyl ether <0.50 ug/L 0.50 EPA-8260 12/12108 12/12108 14:42 mwb HPCHEM I BRL0867 NO <br /> 2-Hexanone <10 ug/L 10 EPA-8260 12/12108 12/12108 14:42 mwb HPCHEM I BRL0867 N.1 D <br /> Methyl ethyl ketone <10 ug/L 10 EPA-8260 12112/08 12112/08 14:42 mwb HPCHEM I BRL0867 NO <br /> Methyl iodide <2.0 ug/L ZO EPA-8260 12/12108 12/12/08 14:42 mwb HPCHEM 1 BRL0867 NO <br /> Methyl Isobutyl ketone <10 ug/L 10 EPA-8260 12112108 12/12108 14:42 mwb HPCHEM 1 BRL0867 NO <br /> Vinyl acetate <10 ug/L 10 EPA-8260 12/12108 12/12/08 14:42 mwb HPCHEM 1 BRL0867 NO <br /> 1,2-Dicbloroethane-d4(Surrogate) 111 % 76-114 (LCL-UCL) EPA 8260 12/12/08 12/12108 14:42 mwb HPCHEM 1 BRL0867 <br /> Toluene-d8(Surrogate) 101 % 88-110 (LCL-UCL) EPA 8260 12112108 12/12/08 14:42 mwb HPCHEM I BRL0867 <br /> 4-Bromofluorobenzene(Surrogate) 99.8 % 86-115 (LCL-UCL) EPA-8260 12112/08 12112108 14:42 mwb HPCHEM I BRL086-7 <br /> The results in this report apply to the samples analyzed in accordance with the chain of custody document.This analytical report must be reproduced in its entirety. <br /> All results listed in this report we for the exclusive use of the submitting party. BC Laboratories,Inc,assumes no responsibility for report alteration,senlration,detachment or third party interpretation. <br /> 4100 Atlas Court Bakersfield,CA 93308 (661)327-4911 FAX(661)327-1918 www.bCl2bs.com Page 6 of 36 <br /> Certifications: California-ELAP Certification Number 1186; Nevada Administrative Code-NAC-445A <br />