Laserfiche WebLink
UECTOR <br />ENGINEERING, INC. <br />An Ausenco group company <br />Client Name /Project Name: <br />Republic (Allied) / Forward Landfill FU -08 U <br />Sample I. D.: <br />DG -1 (Rec'd 8/12) <br />HYDRAULIC CONDUCTIVITY <br />FIXED WALL <br />ASTM D- 2434. Modified <br />rim <br />021605.09 <br />oil <br />uescnprlon: Report Date: <br />Poorly Graded Gravel w/ Sand (GP) August 13, 2009 <br />TRIAL <br />WATER <br />DRY <br />HYDRAULIC <br />NUMBER <br />CONTENT <br />DENSITY <br />CONDUCTIVITY <br />pcf kg/m^3 <br />cm/sec <br />Initial <br />14.4 <br />90.8 1454 <br />1 <br />5.5E+00 <br />2 <br />5.6E+00 <br />3 <br />5.5E+00 <br />4 <br />5.6E+00 <br />5 <br />5.2E+00 <br />6 <br />5.5E+00 <br />Final <br />5.7 <br />AVERAGE: <br />5.5E+00 <br />1.0E+02 <br />1.0E+00 {- <br />0 <br />1 2 3 4 5 6 7 8 <br />TRIAL NUMBER <br />NOTES: 1) Test ran using 7.5 inch diameter fixed wall permeater. Sample Length = 60.5 cm <br />2) CONSTANT HEAD Average Head = 19.5cm <br />F These results apply to the above listed samples. The data and information are proprietary and cannot be released with authorization of Vector Engineering Inc. or client. I <br />By accepting the data and results represented on this page, Client agrees to limit the liability of Vector Engineering, Inc. from Client and all other parties for claims arising out of the use of <br />this data to the cost for the respective test(s) represented hereon, and Client agrees to indemnify and hold harmless Vector from and against all liability in excess of the aformentioned limit. <br />L : Labexcel 1 Projects 1 191 1-fxr Entered By: Reviewed By. -Lab Log. <br />DCN: fwr-rp (rev. 12/16/05) RL V\ 2856A <br />