inspection, Del-Tech reported that the system was offline due to a tripped main breaker <br /> switch. The main breaker switch was reset and the system was restarted. During the July <br /> 29, 2010 inspection, Del-Tech noted that the pump motor in extraction well EW-3R had <br /> failed and was offline. Del-Tech replaced the pump motor on August 13, 2010. During <br /> the August 15 inspection Del-Tech noted that the tower had calcified so that it was not <br /> performing the air stripping process effectively. The system was taken offline for <br /> cleaning and repairs and the system was restarted on August 19, 2010. No other <br /> downtime was reported for the GTF during the monitoring period. It should be noted, <br /> however, that the system was taken offline on October 15, 2010 due to increasing <br /> backpressure in the influent line at the tower. Inspection of the air stripper tower <br /> indicated that the packing material has calcified and needs to be replaced. It is estimated <br /> that the system will be restarted on November 1, 2010 following replacement of the <br /> packing material and other system improvements. <br /> Influent and Effluent Monitoring—During the monitoring period, effluent samples were <br /> collected monthly from the GTF and submitted for analysis of VOCs by EPA Method <br /> 8260B. The July and September 2010 effluent sample were also analyzed for TDS. <br /> Table 1 summarizes the field and analytical results for the GTF during the third quarter <br /> 2010 monitoring period. As shown on Table 1,three VOCs were measured above the <br /> practical quantitation limit(PQL) and one trace level VOC was measured in the effluent <br /> sample collected during the July 2010 sampling event and one trace level VOC was <br /> measured in the effluent sample collected during the August 2010 sampling event. No <br /> VOCs were detected in the effluent sample collected during the September sampling <br /> event. It is believed that sporadic detection of VOCs in the effluent samples collected <br /> during the monitoring period are the result of the calcification of the air stripper. As <br /> discussed above the system was taken offline on October 15, 2010 to make the necessary <br /> repairs to the system to ensure proper groundwater treatment. <br /> GLA hopes that the information provided herein is sufficient for your records. If you <br /> have any questions regarding this notification,please call me at (858) 451-1136. <br /> G o-Logic Associates <br /> l_ <br /> William B. Lope , G, CHg <br /> Project Geologis <br /> c: Don Litchfield, BFI <br /> Enclosure: Table 1 —GTF Influent/Effluent Sample Results and Flow Rate <br /> Analytical Results—TestAmerica <br /> Field Monitoring Reports—Del Tech <br /> 2 <br />