Laserfiche WebLink
Accredited by <br />U.S. Dept. of Commerce <br />LKWU <br />ASBESTOS TEM LABORATORIES, INC WLAP LAB CODE 101891-0 <br />CA DOHS ELAP <br />Jun/17/2010 <br />Don Litchfield <br />Del -Tech Geotechnical Support <br />645 N. Yosemite Ave <br />Oakdale, CA 95361 <br />RE: LABORATORY JOB # 1323-00001 <br />Transmission electron microscopy analytical results for 5 air sample (s). <br />Job Site: <br />Job No.: <br />Enclosed please find results for the TEM analysis of one or more air samples. The analytical procedures were <br />performed according to the NIOSH 7402 (Revision # 1) method. Prior to analysis, samples are checked for <br />damage and disruption of the chain -of -custody seal. Samples are then logged -in, each given a unique laboratory <br />number, and a hard copy containing all pertinent information is generated. This, and all other relevant paper work <br />are kept with each sample throughout the analytical procedures to assure proper analysis. <br />Preparation of air filter cassettes is performed within a HEPA filtered, Class 100 air, laminar flow clean bench <br />environment. Cassettes are wet -wiped to remove any external contamination prior to placement into the clean <br />bench area. Sections of the filters are removed, placed onto glass microscope slides, and collapsed in acetone <br />vapor. The collapsed filters are plasma etched, removing the surface of the filter to a depth of ten percent of its <br />original thickness, then carbon coated. The filters are further sectioned and placed carbon side up onto 200 -mesh <br />copper TEM sample grids in an acetone wick washer to remove filter material. The grids are placed into labeled <br />containers and loaded into the microscope for analysis. <br />TEM analysis is performed on a Philips EM -300 transmission electron microscope operating at 80 or 100 kV, with <br />a magnification as indicated on the analytical report. A known area of the specimen surface is scanned for fibrous <br />structures. All structures exhibiting an aspect ratio greater than or equal to 3 to 1, and a length greater than or equal <br />to 5.0 um are subjected to detailed morphological and selected area diffraction (SAED) analysis. Structures <br />indicated as asbestos, or potentially asbestos, are further analyzed by energy dispersive X-ray (EDX) analysis as <br />needed. Analysis continues until 100 asbestiform structures are found, or an analytical sensitivity of 0.001 <br />structures/cc is attained, or 40 grid openings are analyzed. Data is compiled into a standard report format and <br />released to the client. <br />Sincerely Yours, <br />Laboratory Manager <br />ASBESTOS TEM LABORATORIES, INC. <br />--- These results relate only to the samples tested and must not bereproduced, except in full, with the approval of <br />the laboratory. This report must not be used to claim product endorsement by NVLAP or any other agency of the <br />U.S. Government. --- <br />630 BANCROFT WAY ® BERKELEY, CA 94710 • (510) 704-8930 • FAX (510) 704-8429 <br />www.asbestostemlabs.com With Offices in Reno, NV (775) 359-3377 <br />