My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2010_2
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2010_2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 8:54:07 PM
Creation date
7/3/2020 10:55:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2010_2
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2010_2.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
68
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' Global Presence <br /> Personal Attention <br /> HERST & ASSOCIATES, INC.® <br /> Mr.Rick Jaime n[D �� <br /> California Department of Corrections and Rehabilitation <br /> 7650 S.Newcastle Road/P.O.Box 213004 JUL 3 euid <br /> ' Stockton,CA 95213-9004 ENVIRUNWN T HEALTH <br /> July 29,2010 PERMIT/SERVICES <br /> ' Dear Mr.Jaime: <br /> Summary of Northern California Youth Correctional Center Sampling Results <br /> ' June 2010 <br /> On June 15, 2010, sampling was performed at the Northern California Youth Correctional Center <br /> (NCYCC) to provide supplemental information regarding volatile organic compound (VOC) <br /> concentrations at Well #1,Well#2,Well#4, and the indoor faucet location(Table 1)included in other <br /> recent sampling events. Sampling was performed by Herst & Associates, Inc. VOC analyses were <br /> ' performed by BC Laboratories,Inc. <br /> Well#4(reported to be the primary water supply well for the facility)had no detections during the June <br /> ' 2010 sampling event. <br /> Well #1 (now reported to be a supplemental water supply well that operates about 20% of the year <br /> ' during peak demand periods) exhibited a tetrachloroethene concentration at the MCL. The June 2010 <br /> tetrachloroethene concentration at Well #1 was reported at 5.0 µg/1 compared to an MCL of 5 µg/l. <br /> Trichloroethene was detected at Well#1 during this event at a concentration of 1.0µg/1 compared to an <br /> MCL of 5 µg/1. <br /> ' Well#2 (now reported to be utilized only during short term emergencies, should they occur) exhibited <br /> a tetrachloroethene concentration above the MCL. The June 2010 tetrachloroethene concentration at <br /> Well#2 was reported at 7.1 µg/1 compared to an MCL of 5 µg/1. Trichloroethene was detected at 1.4 <br /> µg/1 compared to an MCL of 5 µg/l. <br /> At the indoor faucet sample location for June 2010,tetrachloroethene was detected at a concentration of <br /> 5.2 µg/l compared to an MCL of 5 µg/l,and trichloroethene was reported at a value of 0.88 µg/1. Herst <br /> & Associates, Inc. understands that the NCYCC experienced a coliform issue in Well #4 prior to this <br /> ' sampling event and as a result supplied water to the NCYC using Well #1 while it addressed the Well <br /> #4 issue. Per correspondence with Mr.Doug Mercer on June 22,2010 and June 23,2010,the NCYCC <br /> treated Well #4 with chlorine and switched back to Well #4 as its primary well on June 22, 2010. <br /> ' During the July 2010 sampling event, the indoor faucet sample location had a tetrachloroethene <br /> concentration of 1.6 µg/1 compared to an MCL of 5 µg/l, and a trichloroethene concentration of 0.21 <br /> µg/1 (estimated value) compared to an MCL of 5 µg/l. The July results confirm that the indoor faucet <br /> VOC concentrations are now below MCLS. <br /> ' Quality assurance samples collected during the June 2010 sampling event included a field blank at Well <br /> #1, a field blank at the indoor faucet, a trip blank, and duplicate samples at Well #2 and the indoor <br /> ' 4630 South Highway 94—North Outer Road Telephone(636)939-9111 <br /> St.Charles,Missouri 63304 Fax(636)939-9757 <br />
The URL can be used to link to this page
Your browser does not support the video tag.