My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_2010_3
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
Archived Reports
>
ARCHIVED REPORTS_2010_3
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/17/2020 8:30:33 PM
Creation date
7/3/2020 10:55:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
ARCHIVED REPORTS
FileName_PostFix
2010_3
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2010_3.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Don Litchfield <br /> March 31, 2010 <br /> Page 3 <br /> Also, during this reporting period, SCS performed monitoring of temporary subsurface evaluation <br /> probe Nos. TGP-01 through TGP-39 (Table 1). Results of this testing indicated that most of these <br /> evaluation probes exhibited methane gas concentrations above the LEL (up to 70.8 percent by <br /> volume). Note, that the methane gas concentrations at these locations,which are for evaluation <br /> purposes and are not compliance locations, have indicated a fluctuating trend. <br /> SCS is scheduled to perform second quarterly monitoring of 2010 (April through June) of the GP <br /> probes by the end of the month of June 2010. <br /> ON-SITE INTERIOR STRUCTURE TESTING <br /> In accordance with the approved testing schedule,the interiors of on-site structures are to be tested <br /> at a minimum, on a quarterly basis. On March 26, 2010, on-site structures (i.e., landfill office, <br /> portable office, scale house, locker room and supply room)were tested for the presence of <br /> methane gas. In each structure, random selected locations (i.e., electrical outlets and junction <br /> boxes, conduits, drains, floor cracks, etc.)were tested. Test results (Table IA) indicated no <br /> methane gas was detected at any accessible location tested. <br /> SCS is scheduled to perform second quarterly monitoring of 2010 (April through June) of the <br /> interiors of on-site structures by the end of the month of June 2010. <br /> STANDARD PROVISIONS <br /> This report addresses conditions at the subject site during the test dates only. Accordingly,we <br /> assume no responsibility for any changes that may occur subsequent to our monitoring which <br /> could affect the quantity of LFG at the subject site or adjacent properties. <br /> Should you have any questions, do not hesitate to contact either of the undersigned. <br /> Very truly yours, <br /> JA"J, <br /> Whitney M. Bills Arthur E. Jones Jr. <br /> Project Professional Project Manager <br /> SCS FIELD SERVICES SCS FIELD SERVICES <br /> cc: Lochlin Caffey—Keller Canyon Landfill <br />
The URL can be used to link to this page
Your browser does not support the video tag.