Laserfiche WebLink
t Global Presence <br /> Personal Attention <br /> HERST & ASSOCIATES, INC.® RECEIVED <br /> C IVED <br /> ' Mr.Rick Jaime <br /> FEB 2 8 2011 <br /> California Department of Corrections and Rehabilitation <br /> 7650 S.Newcastle Road/P.O.Box 213004 ENVIRONMENTAL HEALTH <br /> ' PERMIT/SERVICES <br /> Stockton,CA 95213-9004 <br /> February 25,2011 <br /> Dear Mr.Jaime: <br /> ' Summary of Northern California Youth Correctional Center Sampling Results <br /> January 2011 <br /> ' On January 27, 2011, sampling was performed at the Northern California Youth Correctional Center <br /> (NCYCC) to provide supplemental information regarding volatile organic compound (VOC) <br /> concentrations at Well#1,Well#2,Well#4, and the indoor faucet location(Table 1)included in other <br /> ' recent sampling events. Sampling was performed by Herst & Associates, Inc. VOC analyses were <br /> performed by TestAmerica,Inc. <br /> ' Forward, Inc. has completed a project to provide a 12 inch, looped, city waterline system to the <br /> NCYCC facility. The new city waterline system began supplying city water to the NCYCC on <br /> Tuesday, January 18, 2011. Therefore, during the January 27, 2011 sampling event, the NCYCC was <br /> being supplied solely by the new city waterline system. <br /> Tetrachloroethene and trichloroethene were not detected at Well#4. Well #4 no longer supplies water <br /> to the NCYCC. <br /> ' Well #1 exhibited a tetrachloroethene concentration above the Maximum Contaminant Limit (MCL). <br /> The January 2011 tetrachloroethene concentration at Well #1 was reported at 12 µg/1 compared to an <br /> MCL of 5 µg/1. Trichloroethene was detected at Well#1 during this event at a concentration of 2.4µg/1 <br /> compared to an MCL of 5 µg/1. Well#1 no longer supplies water to the NCYCC. <br /> ' Well #2 exhibited a tetrachloroethene concentration above the MCL. The January 2011 <br /> tetrachloroethene concentration at Well #2 was reported at 7.4 µg/1 compared to an MCL of 5 µg/l. <br /> Trichloroethene was detected at 1.6 µg/1 compared to an MCL of 5 µg/1. Well #2 no longer supplies <br /> water to the NCYCC. <br /> Tetrachloroethene and trichloroethene were not detected at the indoor faucet sample location during the <br /> ' January 2011 sampling event. During the January 2011 sampling event,the indoor faucet was supplied <br /> by the city waterline system and not by NCYCC water supply wells. <br /> Quality assurance samples collected during the January 2011 sampling event included a field blank at <br /> ' Well#2,a field blank at the indoor faucet,a trip blank,and duplicate samples at Well#2 and the indoor <br /> faucet. The field blank sample at Well #2 was collected to provide an indication of VOCs present in <br /> the ambient outdoor air or the laboratory analytical process. The field blank sample at the indoor faucet <br /> ' 4631 North St.Peters Parkway Telephone(636)939-9111 <br /> St.Charles,Missouri 63304 Fax(636)939-9757 <br />