Accredited by <br /> U.S.Dept.of Commerce <br /> P� <br /> d�a11NL KWU <br /> ASBESTOS TEM LABORATORIES, INC NVLAP LAB CODE 101891-0 <br /> CA DOHS ELAP <br /> Jun/30/2011 <br /> Don Litchfield <br /> Del-Tech Geotechnical Support <br /> 645 N.Yosemite Ave <br /> Oakdale,CA 95361 <br /> RE: LABORATORY JOB# 1323-00003 <br /> Transmission electron microscopy analytical results for 5 air sample(s). <br /> Job Site: <br /> Job No.: <br /> Enclosed please find results for the TEM analysis of one or more air samples.The analytical procedures were <br /> performed according to the NIOSH 7402(Revision#1) method. Prior to analysis, samples are checked for damage <br /> and disruption of the chain-of-custody seal. Samples are then logged-in,each given a unique laboratory number,and <br /> a hard copy containing all pertinent information is generated. This,and all other relevant paper work are kept with <br /> each sample throughout the analytical procedures to assure proper analysis. <br /> Preparation of air filter cassettes is performed within a HEPA filtered,Class 100 air, laminar flow clean bench <br /> environment. Cassettes are wet-wiped to remove any external contamination prior to placement into the clean bench <br /> area. Sections of the filters are removed,placed onto glass microscope slides,and collapsed in acetone vapor. The <br /> collapsed filters are plasma etched,removing the surface of the filter to a depth of ten percent of its original thickness, <br /> then carbon coated. The filters are further sectioned and placed carbon side up onto 200-mesh copper TEM sample <br /> grids in an acetone wick washer to remove filter material. The grids are placed into labeled containers and loaded into <br /> the microscope for analysis. <br /> TEM analysis is performed on a Philips CM-12 or EM-300 transmission electron microscope operating at 80 or 100 kV, <br /> with a magnification as indicated on the analytical report. A known area of the specimen surface is scanned for <br /> fibrous structures. All structures exhibiting an aspect ratio greater than or equal to 3 to 1,and a length greater than or <br /> equal to 5.0 um are subjected to detailed morphological and selected area diffraction(SAED)analysis. Structures <br /> indicated as asbestos,or potentially asbestos,are further analyzed by energy dispersive X-ray(EDX)analysis as <br /> needed.Analysis continues until 100 asbestiform structures are found,or an analytical sensitivity of 0.001 <br /> structures/cc is attained,or 40 grid openings are analyzed. Data is compiled into a standard report format and <br /> released to the client. <br /> Sincerely Yours, <br /> Laboratory Manager <br /> ASBESTOS TEM LABORATORIES, INC. <br /> ---These results relate only to the samples tested and must not bereproduced,except in full,with the approval of the <br /> laboratory. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. <br /> Government.--- <br /> 630 BANCROFT WAY • BERKELEY,CA 94710 • (510)704-8930 • FAX(510)704-8429 <br /> www.asbestostemlabs.com With Offices in Reno, NV(775)359-3377 <br />