Laserfiche WebLink
CalRecycle <br /> Disposal Facility Inspection Report (52) <br /> Enforcement Agency: 1county of San Joaquin <br /> SWIS Facility File Number'(99-xx-9999) Inspection Date Program Code <br /> 39-AA-0015 3/31/2011 LEA Periodic <br /> Time In 5:30 PM Time Out Inspection Time <br /> Facility Name Received By <br /> Forward Landfill, Inc. Forward, Inc./Allied Waste North America <br /> Facility Location Owner Name <br /> 9999 S.Austin Road, Manteca 95336 <br /> Inspector Also Present(Name) <br /> Michael Kith lRuben Ramirez, Landfill Manager <br /> THE ABOVE FACILITY WAS INSPECTED FOR COMPLIANCE WITH APPLICABLE SECTIONS OF THE DIVISION 30 OF THE PUBLIC RESOURCES CODE(PRC)AND TITLE 14 AND TITLE 27 CALIFORNIA CODE OF REGULATIONS(CCR) <br /> No violations or Areas of Concern <br /> V' A Regulations <br /> x 20680-Daily Cover <br /> Comments: Exposed waste is observed near active face. <br /> -Provide adequate daily cover at the end of each operating day. <br /> x 20690-Alternative Daily Cover <br /> Comments: The shredded tires used as ADC are larger than 6 inches; Most pieces are larger than 12 inches. <br /> During inspection, the customer has brought in shredded tires that are larger than 6 inches. <br /> -Ensure that shredded tires used as ADC are smaller than 6 inches and meet all the requirement listed in <br /> 27CCR20690(b)(10). <br /> -Tire shreds that do not meet the requirements cannot be counted as reuse and must be disposed of. <br /> X 20820- Drainage and Erosion Control <br /> Comments: There are several erosions on the slopes of the landfill. No waste is exposed. <br /> -Repair all erosions. <br /> -Provide adequate drainage and erosion control to prevent future erosion. <br /> x 20921 -Gas Monitoring and Control <br /> Comments: The concentration of methane gas at G139 is 8%by volume. The concentrations of methane gas <br /> taken during inspection were as following: <br /> Shallow Intermidiate Deep <br /> GP9 8% 0% 0% <br /> GP11 0% 0% 0% <br /> GP12 0% 0% 0% <br /> -Ensure that the methane gas is less than 5%at the property boundary. <br /> - Follow the instruction listed in 27CCR20937. <br /> Inspection Report Comments: <br /> Notes: <br /> 1. The operator has not removed any pieces of the tarp, used as ADC,when the trucks dump new waste near those <br /> tarps. It appears the operator is not ready for the new waste when the trucks begin dumping new waste. At 7:14 AM,the <br /> operator halts the traffic at the active face for 15 minutes so that the operator can remove the tarps used as ACD on the <br /> day before. <br /> 2. According to the operator,the surface water collecting at the base of FU10 will be pumped into the storm water pond. <br />