Forward Landfill LFG Acoustical Analysis Page 5 <br /> May 18, 2011 <br /> Table 2. Noise-Producing Equipment Noise Emissions Ratings <br /> ID Manufacturer Model Raw Atten. Net <br /> LWA dB LWA <br /> dB dB <br /> Prechamber 100.7 15 85.7 <br /> Compressor 1 <br /> Prechamber 100.7 15 85.7 <br /> Compressor 2 <br /> Genset 1 GE JENBACHER J616 122.8 15 107.8 <br /> Genset 2 GS-E22 122.8 15 107.8 <br /> Genset Exhaust GE JENBACHER J616 127.0 48 79.0 <br /> 1 GS-E22, Miratech SCR I _ <br /> Genset Exhaust and GT 201 Silencers 127.0 48 79.0 <br /> 2 <br /> Roof Exhaust Greenheck 97.5 97.5 <br /> Fan 1 <br /> Roof Exhaust 97.5 97.5 <br /> Fan 2 <br /> Radiator 1 Sutton Stromart 98.0 98.0 <br /> Radiator 2 98.0 98.0 <br /> Rooftop Cook 120HLC 1 OD 70.7 70.7 <br /> Exhaust <br /> Gas Blower 1 Kaeser Omega in 84.9 84.9 <br /> Gas Blower 2 ArtUSA 4" Equipment 84.9 84.9 <br /> Enclosure <br /> Chiller I York 102.0 1 1 102.0 <br /> 3 AMBIENT NOISE <br /> The project site is in an active farming area, approximately 2 miles east of Highway <br /> SR99 and a little over 2 miles east of the main runway of Stockton Municipal Airport. <br /> Ambient noise is expected to be consistent with the proximity to these noise sources and <br /> may well exceed the ordinance standards. In the interest of conservatism, the ordinance <br /> standards will therefore be accepted as the criteria for the facility. <br /> 4 PROJECT NOISE <br /> Project sound levels were determined as follows: <br /> 1. A series of acoustic measurements was taken at locations surrounding the <br /> completed Keller Canyon facility while producing power at full capacity. The <br /> one-third octave sound levels and measurement distances were used to compute <br /> the effective sound power level being radiated from each side of the facility. <br /> These levels were compared to levels predicted from the manufacturers' ratings as <br /> shown in Table 2 and found to be in good agreement. Acoustic treatments used in <br /> the Keller Canyon facility are to be duplicated on the Forward project. <br /> 2. The project area topography, locations of noise sensitive uses and measurement <br /> positions and the project facility were entered into the SoundPLAN 7.0 database. <br />