Laserfiche WebLink
1 <br /> ' Global Presence <br /> Personal Attention <br /> HERST & ASSOCIATES, INC <br /> 1 <br /> Mr.Rick Jaime RECEIVED <br /> ' California Department of Corrections and Rehabilitation <br /> 7650 S.Newcastle Road/P.O.Box 213004 J U L 2 9 2011 <br /> ' Stockton,CA 95213-9004 <br /> July 28,2011 ENVIRONMENTAL HEALTH <br /> PERMIT/SERVICES <br /> ' Dear Mr.Jaime: <br /> ' Summary of Northern California Youth Correctional Center Sampling Results <br /> June 2011 <br /> ' On June 30, 2011, sampling was performed at the Northern California Youth Correctional Center <br /> (NCYCC) to provide supplemental information regarding volatile organic compound (VOC) <br /> concentrations at the indoor faucet location (Table 1) included in other recent sampling events. <br /> t Sampling was performed by Herst&Associates,Inc. VOC analyses were performed by TestAmerica, <br /> Inc. <br /> ' Forward, Inc. has completed a project to provide a 12 inch, looped, city waterline system to the <br /> NCYCC facility. The new city waterline system began supplying city water to the NCYCC on <br /> Tuesday, January 18, 2011. Therefore, during the June 30, 2011 sampling event, the NCYCC was <br /> being supplied solely by the new city waterline system. <br /> ' Two common municipal water supply disinfectant bi-products (bromodichloromethane and <br /> chloroform) were detected at the indoor faucet sample location during the June 2011 sampling event. <br /> ' Bromodichloromethane and chloroform are trihalomethanes. Trihalomethanes are commonly <br /> produced as part of the chlorination process utilized by municipal water supplies. The drinking water <br /> standard for trihalomethanes is 80 parts per billion (µg/1). The concentration of trihalomethanes at the <br /> ' indoor faucet in June 2011 (47.3 µg/1)is in compliance with the drinking water standard. <br /> Quality assurance samples collected during the June 2011 sampling event included a field blank at the <br /> ' indoor faucet, a trip blank, and a duplicate sample at the indoor faucet. The field blank sample at the <br /> indoor faucet location was collected to provide an indication of VOCs present in the ambient indoor air <br /> or the laboratory analytical process. The trip blank sample was collected to provide an indication of <br /> ' any VOCs associated with shipment or the laboratory analytical process. The duplicate sample was <br /> collected to provide an indication of sampling and laboratory testing reproducibility. <br /> The June 2011 field blank at the indoor faucet yielded no detections. No VOCs were detected in the <br /> ' trip blank. Duplicate sample results for the June 2011 sampling event were similar to the original <br /> sample results,indicating good reproducibility. <br /> ' 4631 North St.Peters Parkway Telephone(636)939-9111 <br /> St.Charles,Missouri 63304 Fax(636)939-9757 <br /> 1 <br />