Laserfiche WebLink
t Global Presence <br /> HERST & ASSOCIATES, INC Personal Attention <br /> RECEIVED <br /> ' Mr.Rick Jaime APR 2 9 2011 <br /> California Department of Corrections and Rehabilitation <br /> 7650 S.Newcastle Road/P.O.Box 213004 ENVIRONMENTAL HEALTH <br /> Stockton,CA 95213-9004 PERMIT/SERVICES <br /> ' April 28,2011 <br /> ' Dear Mr.Jaime: <br /> ' Summary of Northern California Youth Correctional Center Sampling Results <br /> March 2011 <br /> t On March 31, 2011, sampling was performed at the Northern California Youth Correctional Center <br /> (NCYCC) to provide supplemental information regarding volatile organic compound (VOC) <br /> concentrations at Well#1,Well#2,Well#4,and the indoor faucet location(Table 1) included in other <br /> recent sampling events. Sampling was performed by Herst & Associates, Inc. VOC analyses were <br /> performed by TestAmerica,Inc. <br /> ' Forward, Inc. has completed a project to provide a 12 inch, looped, city waterline system to the <br /> NCYCC facility. The new city waterline system began supplying city water to the NCYCC on <br /> Tuesday, January 18, 2011. Therefore, during the March 31, 2011 sampling event, the NCYCC was <br /> being supplied solely by the new city waterline system. In preparation to decommission Well#1,Well <br /> ' #2, and Well#4,these wells have been removed from service prior to the March 2011 sampling event <br /> (information provided by the NCYCC). Therefore, samples were not able to be obtained at Well #1, <br /> Well#2,and Well#4 during the March 2011 sampling event. <br /> ' Two common municipal water supply disinfectant bi-products, chloroform and <br /> bromodichloromethane, were detected at the indoor faucet sample location during the March 2011 <br /> ' sampling event. Chloroform and bromodichloromethane are trihalomethanes. Trihalomethanes are <br /> commonly produced as part of the chlorination process utilized by municipal water supplies. The <br /> drinking water standard for trihalomethanes is 80 parts per billion (µg/1). The concentration of <br /> t trihalomethanes at the indoor faucet in March 2011 is in compliance with the drinking water standard. <br /> During the March 2011 sampling event, the indoor faucet was supplied by the city waterline system <br /> and not by NCYCC water supply wells. <br /> ' Quality assurance samples collected during the March 2011 sampling event included a field blank at <br /> the indoor faucet, a trip blank, and a duplicate sample at the indoor faucet. The field blank sample at <br /> the indoor faucet location was collected to provide an indication of VOCs present in the ambient indoor <br /> t air or the laboratory analytical process. The trip blank sample was collected to provide an indication of <br /> any VOCs associated with shipment or the laboratory analytical process. The duplicate sample was <br /> collected to provide an indication of sampling and laboratory testing reproducibility. <br /> 4631 North St.Peters Parkway Telephone(636)939-9111 <br /> St.Charles, Missouri 63304 Fax(636)939-9757 <br />