My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AUSTIN
>
9999
>
4400 - Solid Waste Program
>
PR0440005
>
CORRESPONDENCE_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/23/2024 1:48:16 PM
Creation date
7/3/2020 10:56:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2010-2015
RECORD_ID
PR0440005
PE
4433
FACILITY_ID
FA0004516
FACILITY_NAME
FORWARD DISPOSAL SITE
STREET_NUMBER
9999
STREET_NAME
AUSTIN
STREET_TYPE
RD
City
MANTECA
Zip
95336
APN
20106001-3, 5
CURRENT_STATUS
01
SITE_LOCATION
9999 AUSTIN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
FilePath
\MIGRATIONS\SW\SW_4433_PR0440005_9999 AUSTIN_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
637
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Don Litchfield <br />September 28, 2012 <br />Page 3 <br /> <br /> <br />EVALUATION MONITORING PROBE TESTING <br /> <br />During this reporting period, SCS, as directed by the client, discontinued testing of Temporary <br />Subsurface Evaluation Monitoring Probe Nos. TGP-01 through TGP-39. Note that these <br />locations were for evaluation purposes only and are not compliance locations. <br /> <br />Finally, during this reporting period, SCS performed the final monitoring of former compliance <br />probe Nos. GP-7 (D, M, S) through GP-12 (D, M, S). These locations were replaced during the <br />recently approved monitoring network expansion as authorized by the San Joaquin County Local <br />Enforcement Agency and Cal Recycle. Note that these locations will be maintained and <br />monitored for evaluation purposes only and are not compliance locations. See data in Table 1B <br />(Subsurface Evaluation Points). <br /> <br />SCS will perform future monitoring of these locations as directed by RSI. <br /> <br />ON-SITE INTERIOR STRUCTURE TESTING <br /> <br />In accordance with the approved testing schedule, the interiors of on-site structures are to be tested <br />at a minimum, on a quarterly basis. On August 3, 2012, on-site structures (i.e., landfill office, <br />portable office, scale house, locker room and supply room) were tested for the presence of methane <br />gas. In each structure, random selected locations (i.e., electrical outlets and junction boxes, <br />conduits, drains, floor cracks, etc.) were tested. Test results (Table 1A) indicated no methane gas <br />was detected at any accessible location tested. <br /> <br />SCS is scheduled to perform fourth quarterly monitoring of 2012 (October through December) of <br />the interiors of on-site structures by the end of the month of December 2012. <br /> <br />STANDARD PROVISIONS <br /> <br />This report addresses conditions at the subject site during the test dates only. Accordingly, we <br />assume no responsibility for any changes that may occur subsequent to our monitoring which <br />could affect the quantity of LFG at the subject site or adjacent properties. <br /> <br />Should you have any questions, do not hesitate to contact either of the undersigned. <br /> <br />Very truly yours, <br /> Rebecca L. Lucero Sean T. Bass <br />Project Coordinator Project Manager <br />SCS FIELD SERVICES SCS FIELD SERVICES
The URL can be used to link to this page
Your browser does not support the video tag.